- 40 -
Remark: The output performances of the individual pumps [l/h] can differ.
For this reason the above stated values can not be guaranteed but should
rather be regarded as average values from all pumps.
The flow measuring pipe is marked with scale values ranging between 100 – 1000 l/h.
Usually the PKT 960 is only deployed for larger throughput quantities (500 -1000 l/h).
As the floater can no longer sink lower at a flow quantity of approximately 100 l/h, the
automatic switch-off function is no longer operational.
For deployments of such small quantities with
this unit
, there are also flowmeters available
with scales that are marked to cover a range of 60 – 600 l/h, 40 – 400 l/h, and 15 – 150 l/h.
These special flowmeters are available in addition (see Spare Parts List, Page - 45 -).
Important!!! The above stated values only apply for LUPROSIL®.
At LUPRO-GRAIN® and LUPROSIL NC, the flow rate values are
dependant of the temperature.
For these, the unit must be accordingly calibrated.
A calibration must be performed for media which dispose of another specific weight
than water (Luprosil) and the viscosity of which varies dependant of the temperature.
Should, in comparison to the first calibration, such a media feature a temperature
difference of +/- 5, another calibration is required.
Table 3 (according to BASF)
Expenditure quantities for Luprosil® (in %) for moist cereal (whole grains), all corn
types including maize:
Moisture Content
Conservation Period, Months
in %
1
1-3
3-6
6-12
Up to 16
0,35
0,45
0,50
0,55
16-18
0,40
0,50
0,55
0,65
18-20
0,45
0,55
0,65
0,75
20-22
0,50
0,65
0,75
0,85
22-24
0,55
0,70
0,85
0,95
24-26
0,60
0,80
0,95
1,05
26-28
0,70
0,90
1,05
1,15
28-30
0,80
1,00
1,15
1,30
30-32
0,90
1,10
1,25
1,45
32-34
1,00
1,20
1,35
1,60
34-36
1,10
1,30
1,50
1,75
36-38
1,25
1,45
1,65
1,90
38-40
1,40
1,60
1,80
2,05
40-42
1,55
1,75
1,95
2,20
42-44
1,70
1,90
2,10
2,35
44-46
1,85
2,05
2,25
2,55
46-48
2,00
2,20
2,40
2,75
48-50
2,15
2,35
2,60
2,95
If it is intended to immediately further convey acid-conserved corn after the acid treatment, an
intermediate storage of one hour is required. If the immediate subsequent activation of the
blower on to the dosing unit can not be avoided, the expenditure quantity recommended in the
table must be increased by 10%.
Содержание PKT 960
Страница 2: ......
Страница 3: ...3 ...
Страница 6: ......
Страница 48: ... 48 12 5 11 6 13 7 8 9 10 4 16 3 15 Bild 2 image 2 17 14 Bild 1 image 1 ...
Страница 49: ... 49 Bild 3 image 3 Bild 4 image 4 20 4 15 4 13 18 14 4 19 13 11 19 7 8 9 10 ...
Страница 53: ... 53 58 52 60 57 59 53 48 51 57 59 56 54 55 49 20 50 11 62 61 20 64 63 Bild 11 image 11 Bild 12 image 12 ...