Model
SRE 156, SRE 166
SRE 176, SRE 250, SRE 260
Resistance of a Burner Thermistor
85 k
Ω
(3.3.4-3) or less
100 k
Ω
(3.3.4-3) or less
Model
SRE 156, SRE 166
SRE 176, SRE 250, SRE 260
Resistance of a Burner Thermistor
85 k
Ω
(3.3.4-3) or less
100 k
Ω
(3.3.4-3) or less
2 hrs
High
Med - High
Med
3min.
5min.
Item
Test Item
Specifications
Remarks.
Burning lock
Circulation Fan Motor
post-purge after recovery
from a power failure
Prevention of relay stuck
Fixed burning
Stand-by mode
Cleaning function (SRE
250, SRE 260)
Maintains the present burning regardless of changed room temperature when Key-Lock
(Childproof Lock) Button and Extension Button are pressed together more than 5 sec.
This function is canceled when Key-Lock (Childproof Lock) Button is pressed more than
3 sec. or Power Button is turned off.
When the power supply is turned on when F-0 is displayed, if the resistance of the
Burner Thermistor is less than the following values, then a Circulation Fan Motor post-
purge (T12) full-wave is performed.
When a flame is extinguished (Power Button OFF, safety flame extinguish, timer waiting,
power-saving flame extinguish) and 20 min. pass by, if the resistance of a Burner
Thermistor is less than the following values, this function is enabled by Blower Motor P4
rotation and fan motor full-rotation. In addition, when the resistance is the following
values or more, it is disabled.
This applies to the following cases:
If the heater is plugged in but does not operate after 20 min. and an error code is
displayed on the indicator.
Maintains time and burning for T34 15 min. after the Power Button is turned on. When
burning mode is high and fixed, if the mode is changed, after 20 min., if the state of
burning changes, then burning switch safety will not have any influence.
If the Power Button is turned off for 5 min., Information Display, colon, and time
indication LEDs will turn off. While the LEDs are off, pressing any key will return the
display to the current time. If left for an additional 5 min., the display will be turned off by
the Stand-by Mode.
Forcibly changes burning to Med. burning if High burning (including Additional High
burning operation) is performed continuously more than two hours.
-14
-15
-16
-17
-18
-19