Item
Test Item
3.3.1-10
3.3.1-11
3.3.1-12
3.3.1-13
3.3.1-14
3.3.1-15
3.3.1-16
3.3.1-17
3.3.1-18
3.3.1-19
3.3.1-20
3.3.1-21
Blower Motor post-purge
timing 1 (T11)
Fan Motor post-purge
timing (T12)
Burner Thermistor
detection timing (T13)
Setting Possible timing
(T14)
Refueling timing (T15)
Refueling warning timing
(T16)
Burning change timing
(T18)
Motor lock timing (T23)
Pump delay timing (T24)
Blower Motor delay timing
(T25)
Buzzer 5 sec. (T26)
Blower Motor post-purge
timing 2 (T27)
Specifications
SRE 156
SRE 166
15
±
2 sec.
90
±
7 sec.
20 min.
±
80
sec.
10
±
2 sec.
10min.
±
60sec.
120
±
9 sec.
30
±
3 sec.
5
±
2 sec.
3
±
2 sec.
3
±
2 sec.
5
±
2 sec.
90
±
7 sec.
4
±
2 sec.
SRE 176
SRE 250
SRE 260
15
±
2 sec.
90
±
7 sec.
20 min.
±
80
sec.
10
±
2 sec.
10min.
±
60sec.
120
±
9 sec.
30
±
3 sec.
5
±
2 sec.
3
±
2 sec.
3
±
2 sec.
5
±
2 sec.
90
±
7 sec.
4
±
2 sec.
30
±
3 sec.
150
±
10 sec.
20 min.
±
80
sec.
10
±
2 sec.
10min.
±
60sec.
120
±
9 sec.
60
±
5 sec.
5
±
2 sec.
5
±
2 sec.
5
±
2 sec.
5
±
2 sec.
150
±
10 sec.
10
±
2 sec.
30
±
3 sec.
150
±
10 sec.
20 min.
±
80
sec.
10
±
2 sec.
10min.
±
60sec.
120
±
9 sec.
60
±
5 sec.
5
±
2 sec.
5
±
2 sec.
5
±
2 sec.
5
±
2 sec.
150
±
10 sec.
10
±
2 sec.
Remarks.
No Blower Motor post-purge is
available before Fuel Pump is
turned on. The Blower Motor is at
full rotation until initial timing.
When Power Button is turned on
and after T13 timing, Burner
Thermistor starts to detect.
However, when it is in continuous
operation, timing starts from the
beginning of the second pre-heat.
Therefore, Additional High burning
and Low burning can be
performed.
After displaying the remainder of
burning time, Information Display
flashes (countdown from 10). A
fuel lamp turns on and flashes
after countdown.
Timing at which buzzer B sounds
as a Refueling warning.
After Non-detection of motor
timing (T28).
Buzzer C sounds (E-6,
ventilation), or buzzer B sounds
repeatedly 5 sec. (flame
extinguish for refueling).
Max.
Min.
However, unless Main Circuit
Board detects (less than detected
current) Primary flame within 4
sec., it immediately stops
(Insufficient current was detected)
(when BMP (blower motor post-
purge) is set to 0).
– 51 –