Item
Test Item
Specifications
Remarks.
Initial control for Room
Thermistor burning
Save mode operation
Additional High burning
operation (PH operation)
(except SRE 250,
SRE 260)
High burning
Med.-High burning
Med.-Low burning
4
±
1.5 deg.
Regarding set temperature 1 ˚C or
less
Less than 1 ˚C to 0 ˚C or less
More than 0 ˚C
However, if room temperature is
less than 16˚C, Med.-Low burning
will not be performed.
When room temperature
increases by 4 ˚C higher than set
temperature, Save Mode flame
extinguish is performed. When
room temperature decreases to
less than set temperature during
Save Mode flame extinguish,
Main Circuit Board resumes
operation.
If Main Circuit Board is changed
to set temperature (3.3.9-4), when
the following conditions are met
after Burner Thermistor Detection
Timing (T 13) (SRE 250:Additional
High burning timing (T39)), Main
Circuit Board enters Additional
High burning operation.
1) Room temperature is less than
10 ˚C.
2) Set temperature is 5 ˚C higher
than room temperature.
3) Main Circuit Board does not
perform Additional High
burning after starting operation
(including Save Mode ignition)
operation (including safety
ignition) or it passes Additional
High burning timing (T39) after
Additional High burning
operation is finished (however,
it does not count Additional
High burning timing (T39)
during cleaning operation,
burning lock, and refueling
extension).
* When the condition mentioned
above is exited within 5 min., it is
subject to normal temperature
control.
* If there is any forced burning
condition (burning lock, refueling
extension), forced burning has
priority. Also, if there is forced
burning during PH operation,
Main Circuit Board must pass
Additional High burning timing
(T39) for PH operation.
* Main Circuit Board does not
perform Additional high burning
during refueling extension.
* Burning lock in Additional High
burning mode shall be P4 lock.
3.3.3-8
3.3.3-9
3.3.3-10
– 56 –