– 60 –
Item
Test Item
Specifications
Remarks.
INDICATION
Operation Lamp
Timer Lamp
Fuel Lamp
Ventilation Lamp
Clock Indication Lamp
Temperature Indication
Lamp
Timer Indication Lamp
Key-Lock (Childproof lock)
Lamp
Colon Lamp
Information Display
Indication
Error Code
Burning Mode Indication
Save Mode Lamp
Flashing: Under pre-heat,
Lighting: Under operation and Save Mode flame extinguish. *Operation lamp is in static drive.
Lighting: During timer standby, during timer burning, after timer burning.
Flashing: During time setting by timer
Flashing: Low fuel safety operation, during refueling extension.
Lighting: Warning for low fuel.
Flashing: Function for displaying ventilation in ventilation safety mode (currently
displayed are BTH and value calculated for ventilation).
Lighting: Function for displaying ventilation (20 min. burning displayed, 20 min. BTH displayed)
Flashing: Time setting enabled
Lighting: Current time displayed
Flashing: Set temperature adjustable (during operation)
Lighting: Set temperature displayed (during operation)
Flashing: During time setting by timer
Flashing: Burning locking (3.3.9-14)
Lighting: During Key-Lock (childproof lock) operation
Flashing: Current time displayed,
Lighting: Time is displayed on timer, and current time is not set.
Stop: Flashing: Current time and timer's time setting enabled,
Lighting: Current time, timer's time, error code displayed (3.3.6-11)
Operation: Flashing: -
Lighting: Displays set temperature and room temperature, and displays
remaining burning time during low fuel.
E-0: Overheat protection device activates.
F-0: Recovery from power failure, RAM check, backup power is dead.
E-1: Broken wire of Room Thermistor
F-1: Broken wire of Burner Thermistor, Burner Thermistor running short of Preheat,
Burner Thermistor running short of initial preheat
E-2: Initial lost flame, quasi flame detection
E-5: Anti-earthquake unit operation (is one second slower than safety operation)
E-6: Lost flame
E-7: High room temperature
E-8: When motor lock, Blower Motor high rotation and Upper / Lower limit frequency are
detected
E-9: Secondary Flame Rod not detected (except Model SRE 250, SRE 260)
Bar (— —)indication: When extinguish flame with Power Button turned on, other than
Flashing mentioned above(except during timer standby, during
burning by timer).
Refer to 3.3.9-12 on page 68.
PH: Additional High burning
P4: High burning
P3: Med.-High burning
P2: Med. burning
P1: Med.-Low burning
PL: Low burning
P0: Stop (Only Power Button ON is displayed)
See 3.3.9-10 on page 67.
lighting under Save Mode operation
3.3.6
3.3.6-1
3.3.6-2
3.3.6-3
3.3.6-4
3.3.6-5
3.3.6-6
3.3.6-7
3.3.6-8
3.3.6-9
3.3.6-10
3.3.6-11
3.3.6-12
3.3.6-13
Содержание Kamin SRE 166 (Type B)
Страница 3: ...3 1 OUTVIEW AND SPECIFICATIONS OUTVIEW SRE 156 SRE 166...
Страница 4: ...4 SRE 176 SRE 250 SRE 260...
Страница 5: ...5 Oslo SRE 701 SRE 702 SRE 703...
Страница 7: ...7 SRE 250 SRE 260 Fuel Sub Tank...