![Zibro Kamin SRE 166 (Type B) Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/zibro/kamin-sre-166-type-b/kamin-sre-166-type-b_service-manual_3804418054.webp)
S5566N
dummy
4.7M
Ω
SRE 156
SRE 166
SRE 176
SRE 250
SRE 260
0.7
±
0.3
µ
A
1.0
±
0.3
µ
A
1.2
±
0.3
µ
A
0.7
±
0.3
µ
A
0.7
±
0.3
µ
A
1.0
±
0.3
µ
A
1.2
±
0.3
µ
A
0.7
±
0.3
µ
A
0.7
±
0.3
µ
A
1.0
±
0.3
µ
A
1.0
±
0.3
µ
A
0.7
±
0.3
µ
A
0.7
±
0.3
µ
A
0.7
±
0.3
µ
A
1.0
±
0.3
µ
A
0.7
±
0.3
µ
A
0.7
±
0.3
µ
A
0.7
±
0.3
µ
A
1.0
±
0.3
µ
A
0.7
±
0.3
µ
A
0.7
±
0.3
µ
A
1.0
±
0.3
µ
A
1.1
±
0.3
µ
A
0.4
±
0.4
µ
A
Item
Test Item
3.3.2
3.3.2-1
3.3.2-2
3.3.2-3
FLAME DETECTOR
Detected current (Primary
Flame Rod)
Allowable rod leak
resistance (Primary Flame
Rod)
Detected current
(Secondary Flame Rod)
Specifications
0.6
µ
A or more (recommended value: 0.3
µ
A or more)
1.5 M
Ω
or more
0.6
µ
A or more (recommended value: 0.3
µ
A or more)
Remarks.
Meter:Yokogawa 2011-SB2
(class1, range 3
µ
A) used
until T35 (3.3.1-28).
Quasi flame is detected only when
flame detector starts. Unless
current is detected until T7 (3.3.1-
6) repeat it (return to pre-heat). If
it is still not detected at T7, E-2 is
displayed. If detected current is
less than 0.3
µ
A at T7 to T35, E-2
is also displayed.
After T35
Additional High burning
High burning
Med.-High burning
Med. burning
Med.-Low burning
Low burning
* Unless flame current detection
of the following items meets
condition, E-6 is displayed.
* At the condition of detected
current 0.6
µ
A or more
If it is detected more than 2 sec.
at timing of T9 (3.3.1-8),
T10 (3.3.1-9) will not be
performed. If it cannot be
detected more than 2 sec., E-9
error is displayed. (SRE 156, SRE
166, SRE 176)
ROOM THERMISTOR
Max. set temperature
Min. set temperature
28.4
±
3.2 ˚C (8.56, + 1.25 k
Ω
, - 1.14 k
Ω
) (SRE 156, SRE 166)
29.6
±
2.8 ˚C (8.12, + 0.90 k
Ω
, - 0.94 k
Ω
) (SRE 176)
29.6
±
2.8 ˚C (8.12, + 0.90 k
Ω
, - 0.94 k
Ω
) (SRE 250)
27.7
±
3.2 ˚C (8.84, + 1.31 k
Ω
, - 1.17 k
Ω
) (SRE 260)
5.7
±
2.2 ˚C (25.88, + 3.14 k
Ω
, - 2.78 k
Ω
) (SRE 156, SRE 166)
6.7
±
1.8 ˚C (24.54, + 2.43 k
Ω
, - 2.20 k
Ω
) (SRE 176)
6.7
±
1.8 ˚C (24.54, + 2.43 k
Ω
, - 2.20 k
Ω
) (SRE 250)
5.1
±
2.2 ˚C (26.74, + 3.28 k
Ω
, - 2.85 k
Ω
) (SRE 260)
Use Thermistor B constant 4100.
The Resistance at 28 ˚C is 10k
Ω
.
Indicator should be 28 ˚C.
Indicator should be 6 ˚C.
3.3.3
3.3.3-1
3.3.3-2
– 54 –