Data
Hexadecimal
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
A
10
b
11
C
12
d
13
E
14
F
15
A
B
C
D
Set temperature
Room temperature
Normal temperature indication
20 min.burning state
BTH20
Ventilation Lamp turns on.
BTH
Value calculated for ventilation Ventilation Lamp flashes.
SEG 1, 2
(3)
(1)
(2)
SEG 3, 4
Item
Test Item
Specifications
Remarks.
Failure time indication
function
Error message back-up
Ventilation indication
In safety stop (safety and ventilation safety indicated with error code: E-X, F-X), when
Extension Button is pressed more than 3 sec., (time from when Power Button is turned
on to occurrence of failure) is displayed. Failure indication time is calculated with the
following formula:
Formula
t: Failure indication time
A, B, C, D Four-digit LED data values
Four-digit LED
t = (A x 1 hour + B x 10 min. + C x 1 min. + D x 10 sec.)
However, 0 to 9 sec. are an error.
Data is displayed in hexadecimal and the pattern is as follows:
If UP Button and DOWN Button are pressed together more than 5 sec. when Power
Button is off, up to nine previous error codes will be flashed in order. The Clock
Indication Lamp and Colon lamp are off.
[XE ]or[XF (X = 1-9)
[XE - - ] (ventilation is in bar indication)
When no error previously occurred: [E]
(Example: 1E- 0, 2F- 1)
Stop for refueling is not indicated.
When UP and DOWN Buttons are pressed together for 10 sec. while the heater is in
operation, the indication is changed.
For BTH, BTH20, and the value calculated for ventilation (Z), see 3.3.5.
For 20 min. burning state, see Burning mode indication function (3.3.9-10).
Item (1) to (3) are displayed when UP and DOWN are pressed together for 10 sec.
In this mode, the following items are enabled.
Flame display is possible.
Set temperature change, burning lock, timer setting, Key-Lock (Childproof Lock), and
Save mode are enabled. (the ventilation lamp indicates the states)
Displays the total value when Z +20.
This function is canceled when the flame is extinguished, and when operation is
resumed, the temperature indication will return to normal.
When the heater does not pass T13, (1) [P-00] (2)[**00] are displayed (** indicate the
present BTH).
During safety timing (T33) after passing T13, the value calculated for ventilation is [00].
3.3.9-11
3.3.9-12
3.3.9-13
– 68 –