FUEL NOZZLE:
(23) Remove two (2) screws from the Fuel Nozzle.
CAUTION
Do not lose the Fuel Nozzle Gasket.
z
BURNER THERMISTOR:
(24) Remove three (3) screws and lift the Heat Chamber Assembly.
CAUTION
Do not break the Burner Thermistor under the Heat Chamber Assembly.
(25) Disengage the Thermistor bushing from the Heat Chamber Assembly.
(26) Pull out the lead wire from the Heat Chamber Assembly. Remove the Burner
Thermistor with the wrenches.
CAUTION
Do not twist the lead wire of the Burner Thermistor when remove it.
z
BLOWER MOTOR:
(27) Remove four (4) screws from Blower Motor Assembly and remove the Blower Motor
assembly.
(28) Remove five (5) screws from Blower Motor Case.
(29) Remove Air Intake Fan and nut (left-screwed)
(30) Remove five (5) screws from Blower Motor Case and remove the Blower Motor Case.
CAUTION
When reassembling the Blower Motor Case and the Blower Motor Base,
be sure that the taped-part of the lead wires of the Blower Motor and Hall
IC passes through the recessed portion of the Blower Motor Case.
(31) Remove two (2) screws of Blower Motor.
z
FUEL PUMP:
(32) Disassemble the Fuel Pipe with double wrenches. Remove two (2) screws, then pull
up the Fuel Pump slowly.
CAUTION
Do not mix these screws with other screws since these screws are
special.
z
DEODORIZING PUMP:
(33) Remove the two (2) screws from Deodorizing Pump.
z
FLOAT SWITCH:
(34) Remove the Float Switch by turning counterclockwise with large size pliers.
CAUTION
When reassembling the Float Switch, securely position the Switch so that
it is not caught with the Removable Fuel Tank.
z
CIRCULATION FAN MOTOR:
(35) Remove four (4) screws of the Circulation Fan Cover to dismount it.
(36) Remove four (4) screws of the Circulation Fan Motor.
z
REFLECTOR ASSEMBLY:
(37) Remove six (6) screws of front side and four (4) screws of rear side and pull up the
Reflector assembly.
z
HIGH LIMIT SWITCH:
(38) Disconnect two (2) terminals on the side of Air Duct assembly.