7 : 1
7 : 1
8 sec.
2 sec.
3 sec.
Fan Motor Post Purge Timing (T12)
Half-
wave
3 : 1
Fan Motor Post Purge Timing (T12)
Full-wave
Item
Test Item
Specifications
Remarks.
Min., DOWN Button
Hour, UP Button
Extension Button
(SRE 176)
Key-Lock (Childproof
Lock) Button
Save Mode Button
(except Oslo, SRE 701,
SRE 702 and SRE 703)
CIRCULATION FAN
MOTOR CONTROL
Fan motor half-wave
control setting
When temperature displays:
Press this button once to change temperature setting. If pressed within 10 sec.,
temperature decreases by one degree.
When current time and timer displayed:
Press this button once to change current time and timer. If pressed within 10 sec., clock
increases one min. Press this button more than one sec. to fast-forward the clock. If
time is not set when this button is pressed, the setting will become 0:00 (buzzer sounds
only once when this button is held down).
When temperature displays:
Press this button once to change temperature setting. If pressed within 10sec
temperature increases by one degree.
When current time and timer displayed:
Press this button once to change current time and timer. If pressed within 10 sec., clock
increases one hour. Press this button more than one sec. to fast-forward the clock. If
time is not set when this button is pressed, the setting will become 0:00 (buzzer sounds
only once when this button is held down).
When Refueling Remaining time displayed: Starts Fuelling Extension Operation (Refuel
Extension Operation. Please refer to 3.3.9-5)
When Error message displayed: Displays the time when the unit stopped by error.
Press this button more than 3 sec. starts the Key-Lock (Childproof Lock) operation.
During Key-Lock (Childproof Lock) operation, any buttons except Power Button (OFF)
and Key-Lock (Childproof Lock) Button does not work even if they are pressed. If the
operation is in Key-Lock (Childproof Lock) operation, press this button more than 3 sec.
releases Key-Lock (Childproof Lock) operation.
Press this button once changes to Save mode operation and press this button again
releases Save mode operation.
When Circulation Fan Motor half-wave control setting is enabled (3.3.9-3), fan motor
post-purge operates as follows:
However, if the Circulation Fan Motor stops due to an abnormality (except for stop for
refueling) and until initial state timing T8 ends, fan motor post-purge half-wave control
mentioned above will not be performed.
3.3.7-4
3.3.7-5
3.3.7-6
3.3.7-7
3.3.7-8
3.3.8
– 64 –
Additional High burning,
High, and Med.-High burning:
Med. burning:
Med.-Low and Low burning:
Full rotation
7:1 control
3:1 control