Encoder
Installation
025-9567E
47
9
RMT-CTL
jumper to pin 7
PANEL LABELS
The area in between the instant call key columns is designed to hold labels for the keys to the
right of the area. The plastic overlay covering the label area serves to protect and retain the
instant call labels. At the back of this manual are several sheets, each one containing ten
instant call key column labels. These sheets may be removed and placed in a typewriter so
that the labels may be printed with a description of the call(s) generated by the adjacent key.
A colored high-lighter pen can be used on the labels to add a level of priority to certain
instant call keys. The labels are removed from the sheet by cutting on the inside of the bold
line on the border. When cut in this fashion, the label will fit exactly into the label area on the
panel. When printing the labels, keep in mind that the lower right hand instant call key is
reserved as the panel’s
CLEAR
key. Also if the review-before-send option is to be used, then
the lower left hand instant call key acts as the
SEND QUEUE
key for the panel.
For consistency with the operators manual, we suggest that if the review-before-send option
is used, that the lower left hand key should be labeled
REVIEW/SEND
or
SEND QUEUE
and
if possible, this should be coded in a distinctive color. The function of the
CLEAR
key (lower
right hand key) should be shown on its label as
SELECTIVE CLEAR
or
ALL CLEAR
. The
CLEAR
key label, too, should have a distinctive color.
The labels are installed on the panel by lifting the plastic window from the panel until the top
of the window comes free of the retaining lip. A pointed object may help grip the plastic
window from between the columns of the keys. After the labels have been centered in the
area, the plastic window may be inserted under the retaining lip. There should never be a
need to remove the top or bottom trim pieces that hold the plastic overlay.
Included with each panel is a number of red instant call key-tops. These key-tops may
replace the standard clear key tops to add yet another level of priority to some of the keys.
The key-tops are removed by gripping the key-top between your fingers and pulling straight
away from the panel. When replacing the key-top, be sure that the lens area goes over the
LED at the lower part of the key.
Some of the keys of the keyboard area of the encoder may have labels inserted inside them.
The
RESET
,
CLEAR ENTRY
,
ENTER
,
ALERT
, and
SEND
keys all have slots on their left
side to allow small thin labels to be inserted.
CLOCK OPTION
The 24-hour clock option may be added to the encoder at any time. With the clock option,
the encoder will print the starting and ending time of a call sequence to the call log (when
enabled). On the hour, the date will be printed as well. The hours and minutes will be
displayed on the encoder display during idle periods.
Содержание Model 25