Operation
025-9567E
13
KEY ALERT
TYPE
0 Programmable
beeps
1
Slow siren (same as generated by ALERT key)
2
Fast siren (same as generated by ALERT key)
3
Hi/Lo warble (same as generated by ALERT key)
4 Tone
ramp
Displaying the Time
Normally the time will automatically be displayed 30 seconds after the encoder becomes idle.
However, while the display is clear or after a calling sequence the hours and minutes of the
24 hour time may be displayed immediately by pressing the “*” key. Once initiated, the time
will continuously update in the display until a key is pressed. While the time is displayed, the
middle decimal point of the display is illuminated. When the time displays, any previous
keystrokes are lost.
Accessing the Call Stack
As a standard feature, the Model 25 contains 206 programmable call stacks, one call stack for
each of the possible 206 Instant Call buttons. A call stack is specified by a four digit number
which always starts with a leading digit of “0”. The remaining three digits specify which of
the call stacks to access. Since the numbering of the call stacks match the numbering of the
Instant Call keys, the 206 call stacks are not numbered sequentially. Details on Instant Call
key numbering may be found in the next subsection on Instant Call operation. The valid call
stack number ranges are: 000-004, 010-014, 020-024, 030-034, 040-044, 050-053, 100-158,
200-258, 300-358.
Stacking of call stacks is not allowed. To send a call stack press a
SEND
key. If the call stack
number is out-of-range or unprogrammed (contains no keystrokes) then an attempt to send
will cause the stack number to blink and the beeper to sound.
MAKING INSTANT CALLS
Note:
In order for the Instant Call panels to operate, the encoder must be in the instant
call mode of operation (see Installation Section).
The Instant Call panel system consists of an Instant Call panel inside the encoder enclosure
and any additional Auxiliary Instant Call panels in separate enclosures. All panels
communicate to the encoder via an RS-232C serial loop. When an Instant Call key is pressed,
a key address is generated and sent to the encoder. The key address contains the panel, row
and column location of the key, and accesses one of the 206 call stacks. An Auxiliary panel
may be configured with one of three addresses. The panel address may be the same as, or
different than, other panels. If two or more panels are addressed the same, then their keys and
status LEDs will operate in parallel.