Basic System Configuration on the Bench
92
Hardware ID
This parameter is the unit specific hardware ID for the Station Transponder Unit. The
hardware ID was set with the two DIP switches on the transponder board inside the unit.
For primary station units this number will be between 1 and 511. For secondary station
units (usually Model 6204s) this number will be equal to the primary unit number plus
512. See
on page 57 for more details on setting the unit number
with SW1 and SW2.
Master Station Unit
When this box is checked, it defines this Station Transponder Unit as being the primary
unit at this fire station. The VoIP intercom card (if one is used) will always be installed in
the Master Station Unit. Typically, this will be a Model 6203 unit; however, in some cases
a station might have two Model 6204 units installed instead of a Model 6203 and a Model
6204. In those instances, the Model 6204 designated as the Master Station Unit will also
contain the VoIP intercom card.
Controls Station Printer
When this box is checked, it indicates that a printer has been connected to the serial port
connector on the bottom of the Station Transponder Unit. Printers can only be installed on
units that have been set as Master Station Units.
Station I/O Settings
Once you have completed the Station Interface settings you can configure the I/O settings
for that Station Transponder Unit. You can also come back at any time in the future to add
or subtract inputs or outputs.
The Units button is used to open the window from which you can configure the
operational units assigned to the fire station.
Input Definition Settings
Name
This is the name that the system uses internally to identify this sense input. The name can
be from 1 to 30 characters in length and contain both letters and numbers. The name
cannot contain any spaces; however, periods (.) and underscores ( _ ) are allowed. If a
CAD interface is used, this name label will be used in the CAD messages.
Display Name
This is the name that is used on the buttons displayed on the FSA Console user interface.
The name can be from 1 to 30 characters in length and does support the use of spaces.
When choosing this name, you should remember that the buttons are fixed in size and the
name needs to be easy to read even after it has wrapped to try and fit in the space provided.
Содержание 025-9581M
Страница 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Страница 6: ...6 025 9581M ...
Страница 40: ...Creating Console Positions 40 025 9581M ...
Страница 45: ...45 Installing the VoIP Gateway Server ...
Страница 78: ...Configuring Station Transponder Units 78 025 9581M ...
Страница 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Страница 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Страница 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Страница 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...