Planning the System
32
Default IP Addresses
IP equipment from Zetron will typically be configured with an initial IP address. The
following list identifies factory default IP addresses:
• Model 6203: 10.0.0.1 to 10.0.0.50
• Model 6204: 10.0.0.51 to 10.0.0.100
• VoIP Intercom Unit: 10.0.0.101 to 10.0.0.150
• Zetron-supplied FSA PC: 10.0.0.201 to 10.0.0.223
General Order of Installation
The general order of installation for the software components is presented here. While it
can be carried out in another order to support the circumstances of a particular installation
situation without any danger of causing problems, this order ensures that the servers are in
place before the client components.
1.
FSA Server
- on a dedicated machine
2.
CAD Translator
- if it is going to be used in this system the CAD Translator is
installed on the same machine as the FSA Server
3.
FSA Maintenance Utility
- can be installed on any machine in the network that
can communicate with both the FSA Server machine and the console position
computers, it may be installed on multiple machines
4.
FSA Console
- on the computers located at the dispatch operator positions, it may
also be installed on the server machine
At this point you might want to do the initial configuration on the FSA Server, a few client
FSA Console positions, and a few Model 6203 units to confirm their operation and the
operation of the network connecting them. Once you have completed this part of the
process, you can proceed to installing the components that support the VoIP option if you
are using it.
•
VoIP Gateway Server
- on the same machine as the FSA Server, or on a dedicated
machine
•
VoIP Gateway Maintenance Utility
- this is the configuration tool for the VoIP
Server, because of how it interacts with the server and the individual VoIP intercom
units in the system, when possible, it is recommended that it be installed on some
machine in the system other than the VoIP Server or on a laptop computer that is
connected to the network when maintenance needs to be done.
•
UBAM™ Utilities
- these utilities become necessary if the FSA system spans more
than one subnet and the routers that connect the various portions of the overall
network are configured not to pass UDP packet transmissions from one subnet to
Содержание 025-9581M
Страница 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Страница 6: ...6 025 9581M ...
Страница 40: ...Creating Console Positions 40 025 9581M ...
Страница 45: ...45 Installing the VoIP Gateway Server ...
Страница 78: ...Configuring Station Transponder Units 78 025 9581M ...
Страница 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Страница 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Страница 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Страница 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...