Basic System Configuration on the Bench
86
Batch Request Hold Timeout Period
This parameter is measured in seconds and defaults to a value of 600 (10 minutes).
This timer defines the amount of time that a “Batch” request may be buffered waiting to be
told to execute before the FSA Server automatically aborts it and clears the request from
the batch buffer. Setting this parameter to zero disables the timer.
Audio Idle Timeout Period
This parameter is measured in seconds and defaults to a value of 20. The valid range for
this parameter is 0 to 300.
This timer defines the maximum time that the audio communications activity at the
dispatch center can be idle before the FSA Server automatically sets the Station
Transponder Unit PA state to OFF and shuts down communication with the Station
Transponder Unit. Setting this parameter to zero disables the timer.
Station Master Polling Period
This parameter is measured in seconds and defaults to a value of 60 (1 minute). The valid
range for this parameter is 30 to 3600.
This parameter defines how long the FSA Server waits between polling the Station
Transponder Units to confirm the communications link is still operating and to receive
status updates from the units.
Station Retry Timeout Period
This parameter represents the period that the station waits before initiating a retry. It is
measured in seconds and defaults to a value of 10. The valid range for this parameter is 2
to 20.
If the FSA Server sends a message or command out to an Station Transponder Unit and
does not receive a reply back from that station within the time limit set by this parameter,
the FSA Server will mark that Station Transponder Unit as being in a state of
communications failure. Unless the network is operating in a very substandard way, it
should not be necessary to ever increase the setting of this parameter above the default
value. This timer is provided in order to enable the system maintenance technicians to cut
down on spurious communications failure alarms while they are working to cure a known
network problem.
Note
This parameter is for future use and not available to be edited from
the Global Settings window.
Содержание 025-9581M
Страница 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Страница 6: ...6 025 9581M ...
Страница 40: ...Creating Console Positions 40 025 9581M ...
Страница 45: ...45 Installing the VoIP Gateway Server ...
Страница 78: ...Configuring Station Transponder Units 78 025 9581M ...
Страница 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Страница 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Страница 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Страница 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...