Configuring Station Transponder Units
64
Figure 13: The COR Mode
All of the programmable parameters are described in the following paragraphs.
Station or 4 Unit Display
This is the first parameter listed in the Station Configuration Menu. It determines whether
the first column of LEDs on the Model 6203 front panel represents the station status or a
unit (vehicle) status. If the Model 6203 is the primary unit, this parameter is normally set
for
Station status displayed
. If the Model 6203 is a secondary unit (address greater than
512) then this parameter is normally set to
4 Unit Display
.
Unit Enables
This is the second parameter listed in the Station Configuration Menu. This parameter is
used to select which units (vehicles) are active on the Model 6203. Selecting this
parameter displays another menu where individual units can be enabled or disabled. If a
unit is disabled its status will no longer be displayed and its alerts will no longer be
sounded.
Always Sound Unit Alerts
This is the third parameter listed on the Station Configuration Menu. This parameter deals
with how alerts are sounded for units (vehicles) which are not
In Quarters
. Selecting this
parameter from the menu toggles between always sounding unit alerts or only sounding
unit alerts when the unit’s status is
In Quarters
.
Communications Mode
This is the fourth parameter listed in the Station Configuration Menu. This parameter
holds the Communication Mode that the Model 6203 is currently operating under and this
in turn effects the parameters that are displayed in the Station Configuration Menu. When
Содержание 025-9581M
Страница 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Страница 6: ...6 025 9581M ...
Страница 40: ...Creating Console Positions 40 025 9581M ...
Страница 45: ...45 Installing the VoIP Gateway Server ...
Страница 78: ...Configuring Station Transponder Units 78 025 9581M ...
Страница 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Страница 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Страница 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Страница 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...