59
Setting the Unit Number
Table 1: Switch Values for Setting Unit ID
Switch
Description
Address Value
SW2 -1
Address bit 1 (LSB)
1
SW2 -2
Address bit 2
2
SW2 -3
Address bit 3
4
SW2 -4
Address bit 4
8
SW2 -5
Address bit 5
16
SW2 -6
Address bit 6
32
SW2 -7
Address bit 7
64
SW2 -8
Address bit 8
128
SW1 -1
Address bit 9
256
SW1 -2
Address bit 10 (MSB)
(0 = Primary Unit at station,
1 = Secondary Unit)
512
SW1 -3
Not Used
—
SW1 -4
Not Used
—
SW1 -5
Not Used
—
SW1 -6
Not Used
—
SW1 -7
Software Program baud rate select:
OFF = 1200 baud
ON = 9600 baud
—
SW1 -8
J1 mode selection
OFF = Printer mode
ON = Software Program mode
—