181
Wiring Connections to the Model 620x
• In the
Station Configuration Menu
of the Model 620x programming, the unit must
have its
Communications Mode
set for
Wire Line
• The Model 620x 4-wire Receive (R107) pot should be turned all the way down (set
fully counterclockwise)
• Set jumper JP8 (2-wire RCV Impedance) each unit according to whether the
transponder is the primary or secondary unit at that station:
Primary Station Unit = set
JP8
to position “
A
” = 600
Ω
Secondary Station Unit = set
JP8
to position “
B
” = 3.3 k
Ω
• Set jumper
JP5
(FFSK Output Range) to the “
TEL
” position, if FFSK transmit
levels cannot be set high enough, move it to the “
PWR
” position and try again
Basic 4-wire Interface
• In the
Station Configuration Menu
of the Model 620x programming, the unit must
have its
Communications Mode
set for
Wire Line
• The Model 620x 2-wire Receive (R135) pot should be turned all the way down (set
fully counterclockwise)
• Set jumper JP10 (4-wire RCV Impedance) each unit according to whether the
transponder is the primary or secondary unit at that station:
Primary Station Unit = set
JP10
to position “
A
” = 600
Ω
Secondary Station Unit = set
JP10
to position “
B
” = 10 k
Ω
4
3
11
9
1
11
9
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
SW-2
SW-1
Primary Model 6
J5
J4
J3
4
3
11
9
1
11
9
J5
J4
J3
Secondary Model 6
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
SW-2
SW-1
To 4-wire
Wireline Service
Unit Address = 5
Unit Address = 517
TX Pair
PA Audio ComB
TX & 2W RX Audio & FFSK
TX & 2W RX Audio & FFSK
4W RX Audio & FFSK
4W RX Audio & FFSK
PA Busy
PA Audio ComA
PA
Basic 4-wire System
RX Pair
Содержание 025-9581M
Страница 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Страница 6: ...6 025 9581M ...
Страница 40: ...Creating Console Positions 40 025 9581M ...
Страница 45: ...45 Installing the VoIP Gateway Server ...
Страница 78: ...Configuring Station Transponder Units 78 025 9581M ...
Страница 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Страница 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Страница 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Страница 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...