Installing the Station Transponder Units on Site
118
Figure 43: IP-FSA audio levels with Zetron-supplied sound card
Voice 1.55 Vpp
Sine 1.096 Vpp
Sine 0.388 Vrms
Sine -6.0 dBu
Voice -12 dBu
FSA Station to Operator Console
Handset
Paging
Amplifier
Trans-
former
U41
pin 1
R63
R64
Trans-
former
J4
P11
P9
-56 dB
GND
J5
P6
Mic+
Mic-
AGC
Sound
card gains
Wave and
Master
Set to
100%
Trans-
former
600
ohm
load
PA talk
PA receive
Sidetone level
FSA Station 702-9358
FSA Station 702-0240
FSA Station
IP7 PA module
IP-FSA
Server PC
950-0690
Isolation
Interface
Operator
Console
System
Digital VoIP
F.S. Sine = 0 dB
Sine -2.62 dB
Voice -8.62 dB
Operator Console to FSA Station
Handset
Paging
Amplifier,
600 ohm
Load
Trans-
former
R64
Trans-
former
J4
P4
P3
GND
J5
P5
IP7 blue
buttons
Sound
card gain
Line In
Set to
100%
Trans-
former
PA receive
Rx volume
FSA Station 702-9358
FSA Station 702-0240
FSA Station
IP7 PA module
IP-FSA
Server PC
950-0690
Isolation
Interface
Digital VoIP
F.S. Sine = 0 dB
Sine -16.9 dB
Voice -22.9 dB
J3
P11
P9
R137
AGC
R87
AUX Rx
Operator
Console
System
audio
PTT
GND
GND
Voice 1.48 Vpp
Sine 1.05 Vpp
Sine 0.37 Vrms
Sine -6.4 dBu
Voice -12.4 dBu
Voice 3.16 Vpp
Sine 2.23 Vpp
Sine 0.79 Vrms
Sine 0.16 dBu
Voice -6.16 dBu
Voice 0.0027 Vpp
Sine 0.0019 Vpp
Sine 0.0007 Vrms
Sine -61.2 dBu
Voice -67.2 dBu
Voice 2.04 Vpp
Sine 1.44 Vpp
Sine 0.51 Vrms
Sine -3.62 dBu
Voice -9.62 dBu
Voice 1.12 Vpp
Sine 0.80 Vpp
Sine 0.28 Vrms
Sine -8.8 dBu
Voice -14.8 dBu
Voice 0.558 Vpp
Sine 0.395 Vpp
Sine 0.140 Vrms
Sine -14.89 dBu
Voice -20.89 dBu
Voice 0.143 Vpp
Sine 0.101 Vpp
Sine 0.036 Vrms
Sine -26.7 dBu
Voice -32.7 dBu
Voice 1.13 Vpp
Sine 0.801 Vpp
Sine 0.283 Vrms
Sine -8.74 dBu
Voice -14.74 dBu
Pots set to 50%
Pots set to 50%
Voice 0.143 Vpp
Sine 0.101 Vpp
Sine 0.036 Vrms
Sine -26.7 dBu
Voice -32.7 dBu
Содержание 025-9581M
Страница 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Страница 6: ...6 025 9581M ...
Страница 40: ...Creating Console Positions 40 025 9581M ...
Страница 45: ...45 Installing the VoIP Gateway Server ...
Страница 78: ...Configuring Station Transponder Units 78 025 9581M ...
Страница 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Страница 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Страница 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Страница 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...