ZHDN 2500-150
42
Connection unit
www.zepro.com
9.3
Functional schematic drawing
Function
Input signal
Output
signal
Comment
Illustration
Open
C+E+2H
or
C+E (Coil)
U0+U1+U3+U5 Open from vehicle body down
to about 45º
45º
90º
0º
-10º
Lower (Manual)
E+Di6
U1+U2+U4
Without autotilt (Di6 jumpered)
Lower
E+/Di5+/Di6
With autotilt (Di6 NOT jump-
ered)
Lower (Autotilt
down)
E+Di1*+Di5*+/Di6
U1+U3+U5
Tilt down
C+E+Di3
or
C+E+2H
or
C+E (Coil)
U0+U1+U3+U5
45º
90º
0º
-10º
Raise (Manual)
B+Di6
U0+U2
Without autotilt (Di6 jumpered)
Raise
B+/Di2*+/Di6
U0+U2
With autotilt (Di6 NOT jump-
ered)
Raise (Autotilt up) B+Di2+/Di6
U0+U3
Tilt up
B+C+Di3
or
B+C+2H
U0+U3
Tilting up to approximately 45º
45º
90º
0º
-10º
Close
B+C+2H
U0+U3
Close against vehicle body
45º
90º
0º
-10º
Quick opening
C+E
To angle sen-
sor
The angle sensor is activated
for tilt down, operating quick
opening valve V8 in the range
90º - 15º.
45º
90º
0º
15º
Sensor name with /-symbol in front = 0, i.e., no signal.
* Only required at start of motion, after change of sensor, it is ignored until a re-run takes place.
Содержание ZHDN 2500-150
Страница 2: ......
Страница 57: ...ZHDN 2500 150 Specifications 57 www zepro com Image 64 Loading diagram 14 4 Loading diagram ...