![Zepro ZHDN 2500-150 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/zepro/zhdn-2500-150/zhdn-2500-150_installation-instructions-manual_931520039.webp)
ZHDN 2500-150
Connection unit
39
www.zepro.com
9.1.2
Fault codes
If a fault arises, the fault code is shown in the display in the form of a letter for identifying the fault,
followed by numbers and/or number segments for further information, followed by sensor indica-
tion (C) in accordance with the previous page.
In fault codes E, F and U, the numbers (1-9) show which control device/output the fault code
refers to.
1. Fixed control device 1, including two-hand button 2h1
2. Fixed control device 2, including two-hand button 2h2
3. Radio control device, External
4. Coil control device
5. Truck slider control device
6. Radio control device, internal module
7. CS (cabin switch)
8. Control Power
9. Sensor Power
If the system discovers several faults, only the fault code for the fault with the highest priority will be
shown automatically. The display is prioritised in the order in the table below, L/H, E, F, U and A. To
see all faults, press and hold in button C on the control device. Then the system will browse through
the list so that all faults the system has detected are seen.
When the CS is switched off, the system will browse through a list containing the five latest faults
detected before the display goes off.
Fault codes
Identification
Code
1
Code
2
Code
3
Information
Other
L
Low battery voltage
07-35
Voltage measured
H
High battery voltage
07-35
Voltage measured
E
Control device
locked
1
Fixed control device 1 (incl. two-hand
button 2h1 if they are monitored)
2
Fixed control device 2 (incl. two-hand
button 2h2 if they are monitored)
3
Radio control device, external
4
Coil control device
5
Truck slider control device
6
Radio control device, internal
module
7
CS (cabin switch)
Seg-
ment
Segments B, C, E or X will flash
depending on which button signal
locks the control device; a fixed
light indicates pressing the button
for troubleshooting.
Segments B, C, E or X are illumi-
nated depending on which button
locks the control device.
B
C
E
X
In
Out
F
Output short-cir-
cuited/high current
0-9
Which output has short-circuited/
has high current.
1-7 Control device, dis-
played only after the
respective output/func-
tion has been active.
8 Control power
9 Sensor power
Output not con-
nected/cable
breakdown
0-7
Which output is not connected/
has cable breakdown.
Displayed only after the re-
spective output/function has
been active.
A
Internal fault
0-
Contact support if the lift
does not function.
Содержание ZHDN 2500-150