ZS COMP INSTALLATION MANUAL FOR COMPOSITION SHINGLE ROOFS - U.S.
First Module Row, Continued
Align Interlocks with module corners using timing marks.
Attach Interlocks to connect the back corners of the modules,
using the Zep Tool.
Rotate the Zep Tool from Position 1 to Posi-
tion 3.
Do not over-turn.
Over-turning
may prevent next row of modules from
seating properly.
1/2 “
ii
i
Note:
If the Interlock Zeps are showing, the
Interlock is positioned too far to one side.
Attach Interlocks to Rear Edge of Modules
5e
Interlock Part Number 850-1388
Interlock 850-1388, shown above, has two
timing marks that allow for off-center
placement anywhere between the marks
indicated, or 1.5” in either direction.
1/2” gap between
modules
If a nearby Leveling Foot is too
close to the Interlock, refer to
these sections:
•
•
range
Right Position
Left Position