Terminators
Remove the terminating resistors from the drive. Termination is
supplied by the inline terminator plug on the end of the SCSI
signal cable at P7.
Bay Assignment
The CD-ROM device should be installed in upper Bay B, located
above the control panel. Upper Bay C is the acceptable alternate
location if a second floppy disk drive is already installed in Bay
B.
BAY
DEVICE
A
1.44M Floppy Disk Drive (Drive A)
(Always installed)
B
1.2M Floppy Disk Drive
1.44M Floppy Disk Drive (Drive B)
CD ROM (SCSI address 5)
C
525M Tape (SCSI address 2)
DAT (SCSI address 6)
CD ROM (SCSI address 5 - alternate location if floppy disk
drive is in Bay B)