![Zenith z-server lt Скачать руководство пользователя страница 149](http://html1.mh-extra.com/html/zenith/z-server-lt/z-server-lt_user-manual_3435463149.webp)
DigiBoard EISA C/X
The Digiboard EISA C/X (Model IF-0130) is a 16-port multiport
board that can be used to connect up to 128 terminals or printers
to the system, using eight concentrators. Refer to the table at the
beginning of this chapter for slot assignments.
Installation Notes
Set configuration parameters as listed in this appendix.
1.
Boot your system with the configuration ECU disk in drive
A. During the bootup process, the system displays a message
that an unknown board has been found. This board is the
C/X adapter board. Press ESC to continue.
At the main menu, select “Configure System.”
2.
At the next menu, select “View or Edit Details.”
3.
Move the cursor to the “C/X Adapter Board slot.” Place the
cursor on “Dual-Ported Mem Address.....Under 1 Meg” and
press ENTER.
4.
A list of available memory addresses is displayed. Use the
cursor keys to select the correct address:
For the first board in the system, select C8000 as the
address.
For a second board, select C0000 as the address.
Write down addresses you select, because you will have to
inform the software installation program of it. Leave the
“Dual-Prt Mem Enbl/Dsbl” and “Interrupt Configuration”
options as “disabled.”
5.
Select “System Exit” from the pull-down menu. Save your
changes when prompted.
04/APRIL/93 – 595-5484-UU
159
159
C-9
Option Boards