7.9.13. DIAGNOSTIC MODE
format:
dump
This command sets the printer in dump diagnostic mode. In this mode all
data received through the serial port are not interpreted, but printed directly in
ASCII and HEX format 8 bytes per line. The mode can be used for debugging of
wrong commands or failed communication. To exit this mode is necessary to
hold the right button more than 3 seconds (until red light is lit).
7.9.14. GET PRINTER VERSION
format:
GS ?
(without LF in the end) GS = <1Dh>
The printer answer is in the following format – ‘L’VerHigh VerLow 38
bytes text description \0, where VerHigh and VerLow define the version 2.01 =>
0x02 0x01.
7.9.15. DISABLE DATA RECEIVING
format:
GS ‘=’’0’’L’
(no LF at the end) GS = <1Dh>
Disables data receiving until
GS ‘=’’1’’L’
is received
.