![background image](http://html1.mh-extra.com/html/zeka/lp/lp_programming-manual_3301653033.webp)
User’s Manual
33
ZEKA LP
7.4. OPERATION WITH FORMS
7.4.1. START FORM
With this command begins the saving of new form in the operational
memory of the printer. Every command sent to printer between this command
and the command
FE
will be saved in this form. If there is already form with
this name, it must be deleted first with
FK
, otherwise the command will be
rejected.
Format:
FS”Name”
Name
is the form name. It can be up to 8 characters, where are allowed all
ASCII characters between codes 32 and 127 including, without ‘*’. Small and
capital letters did not differ, so “Test” and “TEST” is same form.
Example
:
FS”Test”
7.4.2. END FORM
With this command ends the saving of the form. It is registered in the form
list and is ready to be loaded and executed. If before the command
FE
the
printer is shut down, the entered until this moment information will be lost
from the form and the memory is freed. The command will be rejected if no
form saving has started yet.
format:
FE
7.4.3. LOAD FORM
With this command saved earlier form is stated as active. From that moment
further, this form will be executed automatically when print command is
received. Canceling of form activity is done when new form is loaded or
command
M
or
N
is executed, as well as when the form is deleted.
format:
FR”Name”
Name:
form name. Form with that name must exist.