After receiving this command the printer will set the new communication
speed. To communicate correctly, the serial port settings of the host and the
printer must be the same. Default settings are: 9600 bps, No Parity , 8-bit data,
1 Stop bit.
example
:
Y19,O,7,1
sets 19200 bps, Odd Parity, 7 data bits and 1 Stop
bit.
7.9.7. SELECT/REJECT TEXT PRINTING
format:
@n
n: takes values 0,1,2,3 and4.
0
Reject text printing
1,2,3 or 4
Printing with stated font number
7.9.8. PRINTER INITIALIZATION (RESET)
format:
^@
This command emulates switch off and than switch on of the printer. The
command is unavailable during loading of PCX graphics, user font or while
printer is in DUMP MODE. The command can’t be used in a command file, but
can be sent during all printer operations. The printer will ignore all commands
that are sent to it until the command ^@ is executing. Estimated time – 2
seconds.
7.9.9. FULL PRINTER INITIALIZATION
format:
^default
This command is similar to ^@, as also clears the memory of all graphics,
forms and user fonts, and reloads the default fonts.