Identification: MD-AL-GI-00
Rev. 1.2 07.06.21 - Application: GID
Connext User Manual
Rev. 2.2 10/01/2023
The maximum threshold represents the minimum value (W or %) of output activation, if this value
is not reached, the contact is open (e.g. 2000W
→
power generated, contact open, heat pump off;
battery with SoC = 65%
→
contact open, heat pump off).
When this value is reached, the contact closes and the logic comes into operation. It is kept active
until the minimum threshold (W or %) is verified. The threshold is checked by default every 15
minutes, but it can be changed.
The 24-hour and yearly operating interval can also be defined.
Figure 64 - Setting dry contacts (4)
After the control logics have been created, they appear among the active logics. They can be activated
all at once or alternatively from the homepage. Only the owner and administrator can
activate/change the logics.