Chapter 2_______________________________________Zaxcom Digital Wireless System User’s Manual
30
Common Transmitter Extended Menu
These menu pages contain parameters that are infrequently changed.
Extended Startup Sequence (without any card inserted)
LCD
SYNTH AB
LOWER POWER MODE
IFB IS OFF 0
PCB REVB 0150
VER #-### (03)
***NO CARD***
EXT MENU APR 9
#-### 17:31:17
ZAXCOM V#-###
TRX900 SN:#####
EXTENDED MENU
PRESS UP TO EXIT
(Optional entry – only occurs if Low Power mode has been fully enabled.)
(
PCB REVB
– indicates the printed-circuit board is revision “B”.)
(
#–###
– indicates the version of the firmware loaded.)
(
0150
– Programmable logic device revision code. ‘0000’ means no
timecode input available.)
(
#####
– indicates the transmitter’s serial number, hardwired into the
printed-circuit board.)
Extended Startup Sequence (with a formatted card inserted)
LCD
SYNTH AB
LOWER POWER MODE
IFB IS OFF 0
PCB REVB 0150
VER #-### (03)
FOUND SD CARD
PCB REVB 0150
EXT MENU APR 9
#-### 17:31:17
FOUND # SEGS
MODE=???????
ZAXCOM V#-###
TRX900 SN:#####
EXTENDED MENU
PRESS UP TO EXIT
(Optional entry – only occurs if Low Power mode has been fully enabled.)
(
{03}
– indicates options available: 00-none, 01-record, 02-IFB, 03-IFB &
record.)
(
#
– indicates how many previous recording(s) were found.)
(
???????
– indicates which Transmission Format was set in the Extended
Menu.)