background image

a.2 Technical features

HEBE

Nominal power:

6Kw

Average efficiency:

91%

Heating capacity:

130-150mc

Flue gas temperature:

150°

Power supply:

230V 50Hz

Nominal power absorption:

110W

Pellet tank capacity:

13Kg

Pellet consumption min:

0,4Kg/h

Pellet consumption max:

1,4Kg/h

Digital control display:

YES

Week program:

YES

Room thermostat:

YES

Manual - automatic functioning:

YES

Adjustable feet:

YES

Dimensions:

454x813x592mm

Weight:

100Kg

Fuel:

pellet Ø6mm

Fumes joint diameter:

Ø80mm

Air intake diameter:

Ø35mm

Minimum safety distance from inflammable materials:

200mm

7

Содержание HEBE

Страница 1: ...PELLET STOVE HEBE OPERATING AND MAINTENANCE HANDBOOK...

Страница 2: ......

Страница 3: ...ou may know and use the product at its best as well as ordinarily upkeep it Our authorized technical service remains at Your complete disposal for any necessity Best regards ZANTIA PLEASE NOTE ZANTIA...

Страница 4: ...temperature setpoint c 13 Stand by c 14 Turning off the stove c 15 The menu c 16 User menu c 17 Menu M1 SET CLOCK c 18 Menu M2 Set chrono c 19 Menu M3 Language selection c 20 Menu M4 Stand by c 21 Men...

Страница 5: ...the stove to protect it consider that on the front of the stove the plate should exceed the stove by at least 25 30cm For your safety it is advisable to maintain a distance of at least 20cm between t...

Страница 6: ...fter fixing the problem at its origin ZANTIA is not responsible for inconveniences tampering breakages or any other damage due to non observance of the instructions reported in this handbook The handb...

Страница 7: ...W Pellet tank capacity 13Kg Pellet consumption min 0 4Kg h Pellet consumption max 1 4Kg h Digital control display YES Week program YES Room thermostat YES Manual automatic functioning YES Adjustable f...

Страница 8: ...Dimensions 1 Switch and power socket 2 Air intake 3 Fumes outlet 8...

Страница 9: ...n the installation and test are performed by an authorized ZANTIA assistance center We would like to make clear that the guarantee expires in case of tampering breakages and similar due to non observa...

Страница 10: ...s when used in the same room or space of the device b 2 Moving and transporting Make sure that the devised used for lifting and transporting the stove support its weight which is reported on the ident...

Страница 11: ...ed FIG 2 INSTALLATION WITH AN EXISTING FLUE Flue gas outlet 80 Reach the existing flue horizontally making sure that it presents a minimum section of 200cm and an easy to inspect base for its annual c...

Страница 12: ...mains outlets present the capacity to support the maximum absorption of the stove which is reported on the plate Make sure the system is provided with a norm compliant earthing and differential switch...

Страница 13: ...g 2 c 2 The use of the buttons button Description mode action P1 Decrease temperature TEMPERATURE SETPOINT Decreases the value of the room temperature SETPOINT PROGRAMMING Decreases the selected param...

Страница 14: ...status c 4 Display Display Function Conditions Displayed info DISPLAY Power status parameter name OFF OFF ROOM TEMPERATURE IGN IGNITION ROOM TEMPERATURE FEED PELLET FEED OPERATING ROOM TEMPERATURE OP...

Страница 15: ...LED ON During the second phase after the period of time set in the PR40 parameter has elapsed the auger turns off the auger LED turns off for the period of time set in the PR41 parameter The speed of...

Страница 16: ...is phase after the period of time set in the PR03 parameter the stove cleans the brazier The message Clean brazier scrolls on the display the auger remains ON auger LED ON and runs at the speed set in...

Страница 17: ...g power is automatically brought to the minimum In this case the message Modulate appears on the display figure 10 If the room temperature drops below the set value temperature setpoint the stove retu...

Страница 18: ...e room temperature drops below the set temperature room setpoint minus the threshold set in the PR43 parameter the stove re starts c 14 Turning off the stove To turn off the stove simply press and hol...

Страница 19: ...M2 2 daily programming 01 day chrono on off 02 start 1 day OFF 0 23 50 03 stop 1 day OFF 0 23 50 04 start 2 day OFF 0 23 50 05 stop 2 day OFF 0 23 50 M2 3 weekly programming 01 weekly chrono on off 0...

Страница 20: ...chrono end week on off 02 start end week 1 OFF 0 23 50 03 stop end week 1 OFF 0 23 50 04 start end week 2 OFF 0 23 50 05 stop end week 2 OFF 0 23 50 M2 5 exit set M3 select language 01 Italian set 02...

Страница 21: ...or 2 seconds Press P1 decrease or P2 increase to select M1 The message M1 set clock scrolls across the display figure 13a Fig 13a Fig 13b Select the required day and press P3 figure 13b Next using the...

Страница 22: ...Fig 13f Fig 13 22...

Страница 23: ...nstructs the clock to ignore the command Press P1 decrease and P2 increase to make changes and press P3 to confirm DAILY PROGRAM Menu level selection meaning possible values M2 2 01 CHRONO DAY Enables...

Страница 24: ...lection meaning possible values M2 3 11 START PRG 2 activation time OFF 0 23 50 M2 3 12 STOP PRG 2 deactivation time OFF 0 23 50 M2 3 13 MONDAY PRG 2 reference day on off M2 3 14 TUESDAY PRG 2 on off...

Страница 25: ...d and press P1 decrease or P2 increase to set ON Setting the Start 1 weekend and Stop 1 weekend times sets the period of operation for Saturday while setting the Start 2 weekend and Stop 2 weekend set...

Страница 26: ...progress figure 17 Press P1 or P2 to enable or disable the buzzer and press P3 to confirm c 22 Menu M6 Initial feeding This function is available only when the stove is OFF and allows feeding of the a...

Страница 27: ...aning 3 1 Status of the pellet feeding auger 52 Time out Toff Thermostat status 106 Smoke temperature 1490 Smoke extraction speed c 24 Menu M8 Technical calibrations This menu option is reserved for t...

Страница 28: ...ons d 5 General switch This electronic component of the stove is composed by a 4A fuse and by an electronic filter that protect the stove from electrical overload and electromagnetic inconveniencies d...

Страница 29: ...of the stove Remove the furnace s internal covering accurately clean and remove the incrustations inside the crucible and its space Clean the fans and check the mechanism of the plays and of the fixi...

Страница 30: ...for several seconds When an alarm is reset the stove turns off for a while in the interest of safety In the event of an alarm the alarm LED stays on alarm LED ON and the buzzer if enabled sounds inte...

Страница 31: ...e display Fig 24 f 5 Failed start up alarm This occurs in the event of failed start up phase This alarm is triggered when the temperature of the smoke does not exceed the value of the PR13 parameter w...

Страница 32: ...sage Al 7 alar al 7 Thermal Prot figure 27 appears on the display and the stove turns off Fig 27 f 8 No negative pressure alarm This alarm is triggered when the external pressure switch detects pressu...

Страница 33: ...pellets in the tank Auger without pellets Fill the tank and proceed as indicated for the first lighting of the stove The stove is blocked for an unsuccessful pellet supply Technical problem with the...

Страница 34: ...34...

Страница 35: ...35...

Страница 36: ...ARANTEE CONDITIONS AT THE END OF EACH SEASON IT IS OBLIGATORY TO HAVE THE AUTHORIZED ASSISTANCE CENTER PERFORM A GENERAL CLEANING OF THE THERMO STOVE OTHERWISE THE GUARANTEE WILL EXPIRE HEBE 00 100320...

Отзывы: