f.3 Smoke overtemperature alarm
This alarm is triggered when the smoke sensor detects a temperature above a fixed, read-only value. The message "Al 3
alar al 3 Hot smoke" appears on the display (figure 23) and the stove turns off.
Fig. 23
f.4 Smoke encoder alarm fault
This alarm is triggered when there is a fault with the smoke fan. The stove enters alarm mode and the message "Al
4 alar al 4 Extractor fault" scrolls on the display.
Fig.24
f.5 Failed start-up alarm
This occurs in the event of failed start-up phase. This alarm is triggered when the temperature of the smoke does not
exceed the value of the PR13 parameter within the time set in the PR01 parameter. The message "Al 5 alarm al 5 Failed
start-up" scrolls on the display and the stove enters alarm mode (figure 25).
Fig.25
f.6 No pellets alarm
This alarm is triggered when the temperature of the smoke drops below the value set in the PR13 parameter in operating
mode. The message "Al 6 alar al 6 no pellets" scrolls on the display and the stove enters alarm mode (figure 26).
Fig.26
31