background image

TECHNICAL INSTRUCTIONS FOR WOOD STOVES

 ABC QUADRO AND ABC ROLO 

Summary of Contents for QUADRO

Page 1: ...TECHNICAL INSTRUCTIONS FORWOOD STOVES ABC QUADROANDABC ROLO ...

Page 2: ...he place and the seller you purchased our product from and we will help you with professional advices and technical support Before using the stoves ABC QUADRO and ABC ROLO read this manual carefully as it can provide you important information regarding the safe installation usage and maintenance of these devices CONTENT 1 Technical characteristics of wood stoves 3 2 Safety instructions 4 3 Instala...

Page 3: ...2 Section of ABC QUADRO stove Section of ABC ROLO stove ...

Page 4: ...ft required MEASUREMENT UNIT kg mm mm mm kw Pa ABC QUADRO 160 1190 542 516 9 145 12 ABC ROLO 155 1155 540 517 9 145 12 ø ABC ROLO and ABC QUATRO stoves have robust design The highest quality materials were used in their production and along with a 5 year warranty provide security to a client in the long term usage 3 Figure 1 ...

Page 5: ...ardous to the environment and can damage the wholecombustion system of a stove Ÿ It is prohibited to store flammable materials in the lower compartment of the stove Ÿ It is prohibited to dry the clothes directly on the stove Clothes drying stand must be out of stove irradiation range Ÿ Any modification or alteration of the stove is prohibited Only original parts delivered by ABC PROIZVOD factory can...

Page 6: ...aced with situation that there is not enough fresh air needed for good combustion and reliable operation of thestove In this case it is necessary to provide fresh air to the rear side of the stove Ÿ The stove must be connected to the appropriate chimney that must have a minimum active height of 4 50m Maximum allowable pressure of primary draft is 20Pa thrust in the chimney Diameter of the chimney ...

Page 7: ...quired for complete combustion of gases that are released during the wood burning Secondary air has another role and that is to prevent the forming of soot layers on the stove door glass Ÿ For controlling the secondary air there is a general rule and that is small fire requires a small amount of secondary air and a big fire requires more secondary air Ÿ During the stove operation the secondary air r...

Page 8: ...thoroughly cleaned at the end of every heating season and during the heating season if chimney cleaning is performed or if the chimney is smaller Ÿ Cleaning the flue pipes is performed at the end of the heating season by taking the baffle plates out and cleaning them with a brush and internal parts of the stove with a vacuum cleaner or by scraping deposits of soot if any Ÿ Discharging the ashtray is...

Page 9: ...006 i EN 13240 2001 A2 2004 AC 2007 Certified laboratory that carried out the verification and testing of solid fuel heating devices regarding the compliance with the requirements specified in standards Termoplam Ltd Testing laboratory Republic of Bulgaria Sofia The company ABC PROIZVOD in 2007 introduced a quality management system JUS ISO 9001 2008 which is maintained and improved Since 2013 two add...

Page 10: ......

Reviews: