Table 6.7c Parameter Functions
No.
Name
Function/Use
Default
Setting Range
P 56
Manufacturer-controlled
* The setting value differs depending on the model.
Model
Default
ASE3-4AA 26.50
ASE3-AA 51.40
ASE5-4BZ 44.00
ASE5-BZ 84.00
ASE10 75.00
See the
table on
the left.
0 to 500 A
P 75
Reset/
PU Disconnection/
PU Stop Selection
Selects functions for reset input reception, operation panel
connector disconnection (PU disconnection), and stop via the
“STOP/RESET” button on the operation panel.
Setting
Range
Reset Function
Selection
Operation
Panel
Disconnection
Stop via the
STOP/RESET
Button
0
Always allowed.
1
Allowed when the
protection
function is active.
Operation
continues
when the
operation
panel is
disconnected.
2
Always allowed.
3
Allowed when the
protection
function is active.
Operation
stops when
the operation
panel is
disconnected.
“STOP” is
disabled.
14
Always allowed.
15
Allowed when the
protection
function is active.
Operation
continues
when the
operation
panel is
disconnected.
16
Always allowed.
17
Allowed when the
protection
function is active.
Operation
stops when
the operation
panel is
disconnected.
“STOP” is
always
enabled.
1
0 to 3, 14 to 17
P 77
Parameter Write
Selection
Enables/disables write protection for parameters.
This function can be used to prevent the parameters from being
overwritten by mistake.
Setting
Range
Description
0
Writable only during stop.
1
Write-protected.
2
Writable regardless of the operation status.
2
0, 1, 2
P 80
Manufacturer-controlled
* The setting value differs depending on the model.
See the
table on
the left.
0.40 to 55.00
Model
Default
ASE3 11.00
ASE5 20.00
ASE10 35.00