EM-0146-8
- -
36
6.5 Changing parameter settings
1) Turn on the power (the motor speed is displayed).
2) Enable the parameter setting mode.
A) Press the “MODE” button.
B) Check that “P” appears on the monitor.
C) Turn the “M Dial” to display the target parameter No, and then press the “SET” button.
The currently set value is displayed.
D) Turn the “M Dial” to change the value, and then press the “SET” button. The parameter No.
and the set value are displayed alternately to indicate that the setting has been confirmed.
E) Press the “MODE” button twice to return to the initial display.
When “P” is not displayed, turn the
“M Dial” until “P” appears.
Hz
A
V
MON
P.RUN
PU
EXT
NET
REV
FWD
MODE
MON
P.RUN
PU
EXT
NET
REV
FWD
Hz
A
V
SET
SET