EM-0146-8
- -
25
4.1.5 Installation of regenerative resistors
* Double-check the model and quantity of regenerative resistors prior to installation.
* Be sure to use all regenerative resistors supplied with the unit.
* Regenerative resistors may be excessively heated. Use heat-resistant and fireproof wires and
avoid their contact with the resistors.
* If the regeneration capacity exceeding the standard specification level is required, regenerative
resistors must be exchanged. Consult us separately.
* Pay attention to the installation standards below (Fig. 4.1b).
Table 4.1a Regenerative Resistor
Fig. 4.1b Regenerative Resistor Installation Standards
Fig. 4.1c Brake Unit Installation Standards (ASE10-4CE- Attached)
30 mm or more
30 mm or more
30 mm or more
A
B C
D
Example of Wiring of the
AMSE-4AE Terminal Block
A B C D
P/+ PR
(To AMSE-4AE Main Circuit
Terminal Block)
Regenerative Resistor Model
Applicable
Model
Indicated on
the package
Indicated on
the body
Capacity
W
Mass
kg
Supplied
Quantity
4AE- FR-ABR-H15K FR-ABR-15K
AMSE-
2AE- FR-ABR-15K
402/piece
2.2/piece
4BB- FR-ABR-H22K 530/piece
3.6/piece
AMSE-
2BB- FR-ABR-22K 560/piece
3.0/piece
2
AMSE-4DE- FR-ABR-11K-03
560/piece
3.2/piece
3
100 mm
100 mm