IM 05P01C31-15EN   page 12/12

■ Key Action Setting Parameter

Menu symbol: 

 (KEY)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(F1)

User function key-1 ac-

tion setting

OFF: Disable

A/M: AUTO/MAN switch

C/A/M: CAS/AUTO/MAN switch

R/L1: REM/LCL switch

R/L2: Loop-2 REM/LCL switch

S/R: STOP/RUN switch

CAS: Switch to CAS

AUTO: Switch to AUTO

MAN: Switch to MAN

REM1: Switch to REM

LCL1: Switch to LCL

REM2: Switch to Loop-2 REM

LCL2: Switch to Loop-2 LCL

STOP: Switch to STOP

RUN: Switch to RUN

AT: Auto-tuning

LTUP: LCD brightness UP

LTDN: LCD brightness DOWN

BRI: Adjust LCD brightness

LCD: LCD backlight ON/OFF switch

LAT: Latch release

PID: PID tuning switch

* Loop-2 setting values are 

  unavailable in Single-loop control.

OFF

EASY

(F2)

User function key-2 ac-

tion setting

OFF

(Fn)

User function key-n ac-

tion setting

PID

■ Display Function Setting Parameter 

Menu symbol: 

 (DISP)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(DVB)

Deviation display band

Permits a change in the span of 

deviation shown on the front-panel 

deviation monitor.

 

Displayed only for UT55A.

 

0.0 to 100.0% of PV input range span (EUS).

1.0 % 

of PV 

input 

range 

span

STD

(PCMD)

Active color PV display 

switch

0: Fixed in white

1: Fixed in red

2: Link to alarm 1 (Alarm OFF: white,

 

Alarm ON: red)

3: Link to alarm 1 (Alarm OFF: red,

 

Alarm ON: white)

4: Link to alarm 1 or 2 (Alarm OFF:

white, Alarm ON: red)

5: Link to alarm 1 or 2 (Alarm OFF:

red, Alarm ON: white)

6: PV limit (Within range: white, Out 

of range: red)

7: PV limit (Within range: red, Out of 

range: white)

8: SP deviation (Within deviation: 

white, Out of deviation: red)

9: SP deviation (Within deviation: red, 

Out of deviation: white)

10: Link to DI (ON: red, OFF: white)

0

EASY

(PCH)

PV color change high 

limit

Set a display value when in PV limit 

or SP deviation.

 

-19999 to 30000 (Set a value within 

the input range.)

 

Decimal point position depends on 

the input type.

0

(PCL)

PV color change low limit

0

(BAR1)

Upper bar-graph display 

registration

0: Disable

1:OUT, Heating-side OUT, Internal value 

in Position proportional control

2: Cooling-side OUT

3: PV

4: SP

5: Deviation

6: Loop-2 OUT, Loop-2 heating-side OUT

7: Loop-2 cooling-side OUT

8: Loop-2 PV

9: Loop-2 SP

10: Loop-2 deviation

11 to 16: Disable

17: Feedback input (valve opening)

18: PV terminals analog input

19: RSP terminals analog input

20: AIN2 terminals analog input

21: AIN4 terminals analog input

27: TSP

28: TSP deviation

29: Loop-2 TSP

30: Loop-2 TSP deviation

5

(Heating

/cooling 

type: 1)

STD

(BAR2)

Lower bar-graph display 

registration

(Heating

/cooling 

type: 2)

(Posi-

tion 

propor

-

tional 

type: 

17)

(BDV)

Bar-graph deviation 

display band

0.0 to 100.0% of PV input range span 

(EUS)

1.0 % 

of PV 

input 

range 

span

STD

(GUID)

Guide display ON/OFF

OFF: Nondisplay, ON: Display

ON

(ECO)

Economy mode

OFF: Disable

1: Economy mode ON (All indications 

except PV display OFF)

2: Economy mode ON (All indications OFF)

3: Brightness 10 % (whole indication)

OFF

(BRI)

Brightness

(Dark) 1 to 5 (Bright)

3

EASY

(MLSD)

Least significant digital 

mask of PV display

OFF: With least significant digit

 

ON: Without least significant digit

OFF

STD

(MKTP)

Method for least signifi-

cant digital mask of PV 

display

0: Rounding, 1: Rounding-off

0

STD

■ SELECT Display Setting Parameter

Menu symbol: 

 (CSEL)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

 to 

(CS1 to CS5)

SELECT Display-1 to -5 

registration

Register the operation parameter 

(except the Operation Mode) that is 

frequently modified to display it in the 

Operation Display.

 

OFF, 2301 to 5000, 6701 to 6710

For the setting range, see User’s Manual.

OFF

STD

Use the following table to record SELECT Display setting value.

Parameter

n=1

n=2

n=3

n=4

n=5

CSn

■ Key Lock Setting Parameter 

Menu symbol: 

 (KLOC)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(COM.W)

Communication write 

enable/disable

OFF: Enable, ON: Disable

OFF

STD

(DATA)

Front panel parameter 

data (▼,▲) key lock

OFF: Unlock, ON: Lock

OFF

(A/M)

Front panel A/M key lock

OFF

■ DI Function Registration Parameter

Menu symbol: 

 (DI.SL)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(A/M)

AUTO/MAN switch

Set an I relay number of contact 

input.

Set “OFF” to disable the function.

 

Standard terminals

DI1: 5025, DI2: 5026, DI3: 5027

E1-terminal area

 

DI11: 5041, DI12: 5042, DI13: 5043, 

DI14: 5044, DI15: 5045, DI16: 5046

E2 -terminal area

 

DI21: 5057, DI22: 5058, DI23: 5059, 

DI24: 5060, DI25: 5061, DI26: 5062

E3-terminal area

 

DI31: 5073, DI32: 5074, DI33: 5075, 

DI34: 5076, DI35: 5077

E4-terminal area

 

DI41: 5089, DI42: 5090, DI43: 5091, 

DI44: 5092, DI45: 5093, DI46: 5094

5025

STD

(R/L)

REMOTE/LOCAL switch

5046

(S/R)

STOP/RUN switch 

5026

(CAS)

Switch to CAS

OFF

(AUTO)

Switch to AUTO

OFF

(MAN)

Switch to MAN

OFF

(REM)

Switch to REMOTE

OFF

(LCL)

Switch to LOCAL

OFF

(AT)

Auto-tuning START/STOP 

switch

OFF

(LAT)

Latch release

OFF

(LCD)

LCD backlight ON/OFF 

switch

OFF

(PVRW)

PV red/white switch

OFF

■ DI Function Numbering Parameter

Menu symbol: 

 (DI.NU)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(SP.B0)

Bit-0 of SP number

Set an I relay number of contact input.

 

Set “OFF” to disable the function.

 

Standard terminals 

DI1: 5025, DI2: 5026, DI3: 5027

E1-terminal area

 

DI11: 5041, DI12: 5042, DI13: 5043, 

DI14: 5044, DI15: 5045, DI16: 5046

E2 -terminal area

DI21: 5057, DI22: 5058, DI23: 5059, 

DI24: 5060, DI25: 5061, DI26: 5062

E3-terminal area

 

DI31: 5073, DI32: 5074, DI33: 5075, 

DI34: 5076, DI35: 5077

E4-terminal area

 

DI41: 5089, DI42: 5090, DI43: 5091, 

DI44: 5092, DI45: 5093, DI46: 5094

OFF

EASY

(SP.B1)

Bit-1 of SP number

OFF

(SP.B2)

Bit-2 of SP number

OFF

(SP.B3)

Bit-3 of SP number

OFF

(PN.B0)

Bit-0 of PID number

OFF

STD

(PN.B1)

Bit-1 of PID number

OFF

(PN.B2)

Bit-2 of PID number

OFF

(PN.B3)

Bit-3 of PID number

OFF

(MP.B0)

Bit-0 of manual preset 

output number

OFF

(MP.B1)

Bit-1 of manual preset 

output number

OFF

(MP.B2)

Bit-2 of manual preset 

output number

OFF

(SP.BC)

Bit changing method of 

SP number

0: Status switch 1

 

1: Status switch 2

0

STD

■ AL1-AL3 Function Registration Parameter

Menu symbol: 

 (ALM)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(AL1.S)

AL1 function selection

Set an I relay number. For the items 

other than below, see Communication 

User's Manual.

Ex.) Set the number 4353 for AL1.S 

to use the alarm 1.

Set “OFF” to disable the function.

No function: OFF

Alarm 1: 4353, Alarm 2: 4354

Alarm 3: 4355, Alarm 4: 4357

Alarm 5: 4358, Alarm 6: 4359

Alarm 7: 4361, Alarm 8: 4362

AUTO (OFF) / MAN (ON) status: 4193

REM (ON) / LCL (OFF) status: 4194

STOP (ON) / RUN (OFF) status: 4195

Output tracking (ON) switching signal: 4201

FAIL (Normally ON) output: 4256

4353

STD

(AL2.S)

AL2 function selection

4354

(AL3.S)

AL3 function selection

4355

(OR.S)

OUT relay function 

selection 

OFF

(OR2.S)

OUT2 relay function 

selection

OFF

■ DO Setting Parameter (E1/E2/E3/E4-terminal Area)

Menu symbol: 

 (DO)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(DO1.S)

DO11/DO21/DO31/

DO41 function selection Same as AL1.S

Set “OFF” to disable the function.

 

 

Initial value: 

DO11, DO12, DO13, DO14, DO15, 

DO31, DO32, DO33, DO34, DO35, 

DO41, DO42, DO43, DO44, DO45 = 

OFF

DO21 = 4357, DO22 = 4358,

 

DO23 = 4359, DO24 = 4361, 

 

DO25 = 4362

See left

Table 

below

STD

(DO2.S)

DO12/DO22/DO32/

DO42 function selection

See left

(DO3.S)

DO13/DO23/DO33/

DO43 function selection

See left

(DO4.S)

DO14/DO24/DO34/

DO44 function selection

See left

(DO5.S)

DO15/DO25/DO35/

DO45 function selection

See left

Use the following table to record DO setting value.

Parameter

E1-terminal Area

E2-terminal Area

E3-terminal Area

E4-terminal Area

DO1.S
DO2.S
DO3.S
DO4.S
DO5.S

■ System Setting Parameter

Menu symbol: 

 (SYS)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(R.MD)

Restart mode

Set how the controller should recover from 

a power failure of 5 seconds or more.

CONT: Continue action set before 

power failure. 

MAN: Start from MAN.

 

AUTO: Start from AUTO.

CONT

STD

(R.TM)

Restart timer

Set time between power on and the 

instant where controller starts computa

-

tion. 0 to 10 s

0

(EPO)

Input error preset output

Set preset output value when the 

input burnout or ADC error occurs. 

Manual output is prioritized when 

the input burnout occurs in MAN.

0: Preset output, 1: 0% output

 

2: 100% output

0

STD

(FREQ)

Power frequency

AUTO, 60: 60 Hz, 50: 50 Hz

AUTO

EASY

(QSM)

Quick setting mode

OFF: Disable

 

ON: Enable

ON

(LANG)

Guide display language

ENG: English

FRA: French

GER: German

SPA: Spanish

Depe-nds on 

the model 

and suffix 

codes

(PASS)

Password setting

0 (No password) to 65535

0

■ Error and Version Confirmation Parameter (for display only)

Menu symbol: 

 (VER)

Parameter 

symbol

Name of Parameter

Status record

Display 

level

(PA.ER)

Parameter error status

EASY

(OP.ER)

Option error status

(AD1.E)

A/D converter error status 1 

(AD2.E)

A/D converter error status 2 

(PV1.E)

Loop-1 PV input error status

(PV2.E)

Loop-2 PV input error status

(LA.ER)

Ladder error status 

(MCU)

MCU version

EASY

(DCU)

DCU version

(ECU1)

ECU-1 version (E1-terminal area)

(ECU2)

ECU-2 version (E2-terminal area)

(ECU3)

ECU-3 version (E3-terminal area)

(ECU4)

ECU-4 version (E4-terminal area)

(PARA)

Parameter version

(H.VER)

Product version

(

SER1

)

Serial number 1

(SER2)

Serial number 2 

(MAC1)

MAC address 1 (E3-terminal area)

(MAC2)

MAC address 2 (E3-terminal area)

(MAC3)

MAC address 3 (E3-terminal area)

The parameters for Loop-2 are unavailable in Single-loop control.

■ Parameter Display Level Parameter

Menu symbol: 

 (LVL)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(LEVL)

Parameter display level

EASY: Easy setting mode

 

STD: Standard setting mode

 

PRO: Professional setting mode

STD

EASY

For Professional setting mode, see User’s Manual.

Trademarks

● Our product names or brand names mentioned in this manual are 

  the trademarks or registered trademarks of Yokogawa Electric Corporation.

● Adobe, Acrobat, and Postscript are either registered trademarks or trademarks

  of Adobe Systems Incorporated.

● Ethernet is a registered trademark of XEROX Corporation in the United States.

● Modbus is a registered trademark of Schneider Electric.

● PROFIBUS-DP is a registered trademark of PROFIBUS User Organization.

● DeviceNet is a registered trademark of Open DeviceNet Vendor Association.

● CC-Link is a registered trademark of CC-Link Partner Association.

● We do not use the TM or ® mark to indicate these trademarks or 

  registered trademarks in this manual.

● All other product names mentioned in this manual are trademarks

  or registered trademarks of their respective companies.

•  Authorised Representative in the EEA

  Yokogawa Europe BV. (Address: Euroweg 2 , 3825 HD Amersfoort, The Netherlands) is the 

Authorised Representative of Yokogawa Electric Corporation for this Product in the EEA.

•  Printed Manuals

Model

Description

UT55A, UT52A Digital Indicating Controller (Panel Mounting Type) Operation Guide 

«

Standard Code Model

»

IM 05P01C31-11EN

UT55A, UT52A Digital Indicating Controller (Panel Mounting Type) Operation Guide 

«

Detailed Code Model

»

IM 05P01C31-15EN

UT55A/MDL, UT52A/MDL Digital Indicating Controller (DIN Rail Mounting Type) 

Operation Guide 

«

Standard Code Model

»

IM 05P01C81-11EN

Precautions on the Use of the UTAdvanced Series

IM 05P01A01-11EN

•  Electronic Manuals

  You can download the latest manuals from the following website:

  URL: http://www.yokogawa.com/ns/ut/im/

Model

Description

UT55A, UT52A Digital Indicating Controller (Panel Mounting Type) Operation Guide 

«

Standard Code Model

»

IM 05P01C31-11EN

UT55A, UT52A Digital Indicating Controller (Panel Mounting Type) Operation Guide 

«

Detailed Code Model

»

IM 05P01C31-15EN

UT55A/MDL, UT52A/MDL Digital Indicating Controller (DIN Rail Mounting Type) 

Operation Guide 

«

Standard Code Model

»

IM 05P01C81-11EN

UT55A/UT52A Digital Indicating Controller User’s Manual

IM 05P01C31-01EN

UTAdvanced Series Communication Interface (RS-485, Ethernet) User’s Manual IM 05P07A01-01EN
UTAdvanced Series Communication Interface (Open Network) User’s Manual

IM 05P07A01-02EN

LL50A Parameter Setting Software Installation Manual

IM 05P05A01-01EN

LL50A Parameter Setting Software User’s Manual

IM 05P05A01-02EN

Precautions on the Use of the UTAdvanced Series

IM 05P01A01-11EN

•  General Specification

Model

Description

UT55A, UT52A Digital Indicating Controller (Panel Mounting Type)

GS 05P01C31-01EN

UT55A/MDL, UT52A/MDL Digital Indicating Controller (DIN Rail Mounting Type) GS 05P01C81-01EN
LL50A Parameter Setting Software

GS 05P05A01-01EN

The last two characters of the manual number and general specification number indicate the 

language in which the manual is written.

Содержание UTAdvanced UT52A

Страница 1: ...ish are available for the guide display 2 For heating cooling output both Output 1 and Output 2 should be specified Not available when Output 2 is N For position proportional output specify P for Outp...

Страница 2: ...o 5 000 V 0 1 of instrument range 1 digit DC voltage 0 000 to 2 000 V 0 2 of instrument range 1 digit 0 00 to 10 00 V 0 1 of instrument range 1 digit DC voltage for high input impedance 0 000 to 1 250...

Страница 3: ...208 Can be used for retransmission output or 15 V DC loop power supply when current voltage pulse output is not used for control output Current output range can be changed In Position proportional ty...

Страница 4: ...nal contact output Transistor contact rating 24 V DC 50 mA DO22 DO21 DO23 DO24 DO25 COM Alarm 4 PV low limit Common UT Option code Y2 307 308 309 310 311 312 Function can be assigned to the terminals...

Страница 5: ...ting Software is on the top of the unit 2 Setup Procedure The following flowchart shows the setup procedure for UT55A and UT52A Install and wire a controller Monitoring and control of regular operatio...

Страница 6: ...type is displayed Press the SET ENTER key 5 6 Energized De energized Latch action Stand by action The alarm 1 type setpoint 02 PV low limit is registered After the setup is completed press the DISPLAY...

Страница 7: ...int has been registered This starts auto tuning The limiter can be set to the output during auto tuning For details see User s Manual IM 05P01C31 01EN The MAN lamp goes off which means that the auto t...

Страница 8: ...function E1 to E4 terminal areas Faulty Contact us for repair Normal indication Normal indication Rightmost decimal point on PV display blinks Setup parameter PA ER Calibration value error Initialized...

Страница 9: ...4 SP low limit 05 Deviation high limit 06 Deviation low limit 07 Deviation high and low limits 08 Deviation within high and low limits 09 Target SP high limit 10 Target SP low limit 11 Target SP devia...

Страница 10: ...king state allows you to make changes setting mode Use the Up Down Left Right arrow keys to change the setpoint Press the SET ENTER key to register the setting Note that there are some parameters whic...

Страница 11: ...ge O1RS Retransmission output type of OUT current output Same as RTS OFF STD O1RH Maximum value of retransmission output scale of OUT current output When O1RS PV1 SP1 PV2 SP2 TSP1 TSP2 PV RSP AIN2 or...

Страница 12: ...ion Set an I relay number For the items other than below see Communication User s Manual Ex Set the number 4353 for AL1 S to use the alarm 1 Set OFF to disable the function No function OFF Alarm 1 435...

Отзывы: