Brief Description of Parameter Map

The control prevents unintentional change of the function.
The parameter display level is just a function to hide the display so the set function works.

Changing of parameter display level
The parameters to be displayed can be controlled by changing the setting value for setup parameter LEVL.

Setting value

EASY

EASY

Symbol

 

Corresponding parameters are displayedin all modes.

STD

Symbol

Symbol

PRO

PRO

Symbol

Symbol

Symbol

Corresponding parameters are displayed only in Professional setting mode.

Meaning of Parameter Symbol and Numeric Value

Numeric Value

Symbol

Group

  

Parameter symbol

Group E1: indicates the parameter in E1-terminal area

E3: indicates the parameter in E3-terminal area
E4: indicates the parameter in E4-terminal area
1 to 4, R: indicate the group numbers

Display may be controlled according to the setting value of the setup parameter and operation status.

Parameter Display Transition and Setup Operation

To move to the Operation Parameter Setting Display

To move to the Setup Parameter Setting Display

To move to the Operation Display

<Operation for Setting>

Parameter Display Level

If you cannot remember how to carry out an operation during setting, press the DISPLAY key or DISP key once. This
brings you to the display (Operation Display) that appears at power-on.

Corresponding parameters are displayed only in Standard setting mode and Professional setting mode.
Parameter display level indicators "EASY" and "PRO" are unlit in Standard setting mode.

The parameter display level is a function to control the parameters to be displayed. The factory setting is
LEVL=STD.

To select the parameter setting displayed as the initial value, press the Down arrow key to move to the next parameter.
To change and set the parameter setting, press the SET/ENTER key to start the setpoint blinking. The blinking state allows
you to make changes (setting mode). Use the Up/Down/Left/Right arrow keys to change the setpoint. Press the
SET/ENTER key to register the setting.

Press the key
for 3 seconds.

/

Press the key
for 3 seconds.

/

Page 5 / 18

Содержание UTAdvanced UT35A

Страница 1: ...UTAdvanced UT35A UT32A Digital Indicating Controller Parameter Maps and Lists TI 05P01D31 01EN Copyright July 2011 1st Edition July 2011 Page 1 18...

Страница 2: ...Map PRO This sheet describes the setup parameter map which can be used as an operation guide List of Parameters PRO This sheet describes the setting range and initial value of operation parameters an...

Страница 3: ...l output value OUT and measured input value PV The data to be displayed can be set by the parameter Initial value deviation in Heating cooling control heatingside control output Lit when the alarms 1...

Страница 4: ...nu Display Press the key once to cancel the parameter setting setpoint is blinking SET ENTER key Press the key in the Menu Display to move to the Parameter Setting Display of the Menu Press the key in...

Страница 5: ...ion and Setup Operation To move to the Operation Parameter Setting Display To move to the Setup Parameter Setting Display To move to the Operation Display Operation for Setting Parameter Display Level...

Страница 6: ...ET ENTER key to blink the setpoint 6 Press the Up or Down arrow key to change the setpoint 7 Press the SET ENTER key to register the setpoint the setpoint stops blinking 8 Press the PARAMETER key once...

Страница 7: ...How to Set Parameter Setpoint Numeric Value Setting Selection Data Setting Time minute second Setting Page 7 18...

Страница 8: ...segments Alphabet Symbol display and Data display 11 segments Alphabet Group display 7 segments Alphabet PV display 14 segments Symbol The following shows the parameter symbols menu symbols alphanumer...

Страница 9: ...N2 1 Ic 4 Ic R Ic MPO5 DYN3 1 Dc 4 Dc R Dc END DYN4 1 OHc 4 OHc R OHc Symbol Corresponding parameters are displayedin all modes DYF1 1 OLc 4 OLc R OLc DYF2 1 HYSc 4 HYSc R HYSc DYF3 1 DB 4 DB R DB Sym...

Страница 10: ...l Key Lock Setting Menu Lock Setting DI Function Registration DI Function Numbering DI1 DI2 Contact Type Setting DI Setting E1 terminal area DI Setting E4 terminal area AL1 AL3 Function Registration D...

Страница 11: ...tch action 0 AL2 Alarm 2 type EASY PV low limit 02 Without Standby action 0 Energized 0 Latch action 0 AL3 Alarm 3 type EASY PV high limit 01 Without Standby action 0 Energized 0 Latch action 0 AL4 Al...

Страница 12: ...0 0 In Position proportional control 1 0 to 10 0 3 0 PO Preset output Heating side preset output in Heating cooling control EASY 5 0 to 105 0 0 0 SU PO Sub preset output in Two position two level cont...

Страница 13: ...ins Mfg Co ASTM E988 WRE W97Re3 W75Re25 OFF UNIT PV input unit EASY No unit C Degree Celsius No unit No unit No unit F Degree Fahrenheit C RH Maximum value of PV input range EASY Depends on the input...

Страница 14: ...PRO 0 00 HDF2 Heater break alarm 2 Offdelay timer PRO 0 00 HB1 D Heater break alarm 1 contact type PRO CLS HB2 D Heater break alarm 2 contact type PRO CLS RS 485 Communication Setting E1 terminal are...

Страница 15: ...isplay CC Link Communication Setting Menu Symbol Name Display level Setting range Initial value User setting CC L BR Baud rate EASY 156K 156k bps 625K 625k bps 2 5M 2 5M bps 5M 5M bps 10M 10M bps 10M...

Страница 16: ...ELECT Display 5 registration STD OFF CS10 SELECT parameter 10 registration PRO OFF CS11 SELECT parameter 11 registration PRO OFF CS12 SELECT parameter 12 registration PRO OFF CS13 SELECT parameter 13...

Страница 17: ...DIn5 contact type PRO 0 n Terminal area number 1 to 4 AL1 AL3 Function Registration Menu Symbol Name Display level Setting range Initial value User setting ALM AL1 S AL1 function selection STD 4353 AL...

Страница 18: ...r setting INIT U DEF Initialization to user default value PRO 12345 Initialization automatically returned to 0 after initialization 0 F DEF Initialization to factory default value PRO 12345 Initializa...

Отзывы: