UTAdvanced UT35A/UT32A

Names and Functions of Display Parts

UT35A Display Parts

UT32A Display Parts

No. in figure

(1)

(2)

(3)
(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

Lit while the ladder program operation is executed.

Ladder operation indicator
(green)

Displays PV. Displays an error code if an error occurs. Displays the scrolling guide in the
Menu Display and Parameter Setting Display when the guide display ON/OFF is set to ON.

Description

Displays a group number (1 to 4, or R) and terminal area (E1 to E4). 1 to 4 represent SP
numbers in the Operation Display. R and E1 to E4 are displayed in the Parameter Setting
Display.
Displays a parameter symbol.

Parameter display level
indicator
(green)

Status indicator
(green and red)

Security indicator (red)

Displays a parameter setpoint and menu symbol.
Displays control output value (OUT) and measured input value (PV).
The data to be displayed can be set by the parameter.
Initial value: deviation, in Heating/cooling control: heatingside control output

Lit when the alarms 1 to 4 occur.
Event displays other than alarms can be set by the parameter.

Lit or blinks when the Up/Down or Left/Right arrow key operation is possible.

Displays the setting conditions of the parameter display level function.
 Parameter display level             EASY          PRO
 Easy setting mode                    Lit              Unlit
 Standard setting mode              Unlit           Unlit
 Professional setting mode          Unlit           Lit

Displays the operating conditions and control status.
 Display        Description
 REM            Lit when in remote mode (REM).
 MAN           Lit when in manual mode (MAN). Blinks during auto-tuning.

Lit if a password is set. The setup parameter settings are locked.

Data display (orange)

Bar-graph display
(orange and white)

Event indicator (orange)

Key navigation indicator
(green)

Name

PV display
(white or red)

Group display
(green)

Symbol display (orange)

Page 3 / 18

Содержание UTAdvanced UT35A

Страница 1: ...UTAdvanced UT35A UT32A Digital Indicating Controller Parameter Maps and Lists TI 05P01D31 01EN Copyright July 2011 1st Edition July 2011 Page 1 18...

Страница 2: ...Map PRO This sheet describes the setup parameter map which can be used as an operation guide List of Parameters PRO This sheet describes the setting range and initial value of operation parameters an...

Страница 3: ...l output value OUT and measured input value PV The data to be displayed can be set by the parameter Initial value deviation in Heating cooling control heatingside control output Lit when the alarms 1...

Страница 4: ...nu Display Press the key once to cancel the parameter setting setpoint is blinking SET ENTER key Press the key in the Menu Display to move to the Parameter Setting Display of the Menu Press the key in...

Страница 5: ...ion and Setup Operation To move to the Operation Parameter Setting Display To move to the Setup Parameter Setting Display To move to the Operation Display Operation for Setting Parameter Display Level...

Страница 6: ...ET ENTER key to blink the setpoint 6 Press the Up or Down arrow key to change the setpoint 7 Press the SET ENTER key to register the setpoint the setpoint stops blinking 8 Press the PARAMETER key once...

Страница 7: ...How to Set Parameter Setpoint Numeric Value Setting Selection Data Setting Time minute second Setting Page 7 18...

Страница 8: ...segments Alphabet Symbol display and Data display 11 segments Alphabet Group display 7 segments Alphabet PV display 14 segments Symbol The following shows the parameter symbols menu symbols alphanumer...

Страница 9: ...N2 1 Ic 4 Ic R Ic MPO5 DYN3 1 Dc 4 Dc R Dc END DYN4 1 OHc 4 OHc R OHc Symbol Corresponding parameters are displayedin all modes DYF1 1 OLc 4 OLc R OLc DYF2 1 HYSc 4 HYSc R HYSc DYF3 1 DB 4 DB R DB Sym...

Страница 10: ...l Key Lock Setting Menu Lock Setting DI Function Registration DI Function Numbering DI1 DI2 Contact Type Setting DI Setting E1 terminal area DI Setting E4 terminal area AL1 AL3 Function Registration D...

Страница 11: ...tch action 0 AL2 Alarm 2 type EASY PV low limit 02 Without Standby action 0 Energized 0 Latch action 0 AL3 Alarm 3 type EASY PV high limit 01 Without Standby action 0 Energized 0 Latch action 0 AL4 Al...

Страница 12: ...0 0 In Position proportional control 1 0 to 10 0 3 0 PO Preset output Heating side preset output in Heating cooling control EASY 5 0 to 105 0 0 0 SU PO Sub preset output in Two position two level cont...

Страница 13: ...ins Mfg Co ASTM E988 WRE W97Re3 W75Re25 OFF UNIT PV input unit EASY No unit C Degree Celsius No unit No unit No unit F Degree Fahrenheit C RH Maximum value of PV input range EASY Depends on the input...

Страница 14: ...PRO 0 00 HDF2 Heater break alarm 2 Offdelay timer PRO 0 00 HB1 D Heater break alarm 1 contact type PRO CLS HB2 D Heater break alarm 2 contact type PRO CLS RS 485 Communication Setting E1 terminal are...

Страница 15: ...isplay CC Link Communication Setting Menu Symbol Name Display level Setting range Initial value User setting CC L BR Baud rate EASY 156K 156k bps 625K 625k bps 2 5M 2 5M bps 5M 5M bps 10M 10M bps 10M...

Страница 16: ...ELECT Display 5 registration STD OFF CS10 SELECT parameter 10 registration PRO OFF CS11 SELECT parameter 11 registration PRO OFF CS12 SELECT parameter 12 registration PRO OFF CS13 SELECT parameter 13...

Страница 17: ...DIn5 contact type PRO 0 n Terminal area number 1 to 4 AL1 AL3 Function Registration Menu Symbol Name Display level Setting range Initial value User setting ALM AL1 S AL1 function selection STD 4353 AL...

Страница 18: ...r setting INIT U DEF Initialization to user default value PRO 12345 Initialization automatically returned to 0 after initialization 0 F DEF Initialization to factory default value PRO 12345 Initializa...

Отзывы: