IM 12D08N04-01E
5-29
5. Parameter Setting
Code
User interface
50
51
52
53
54
55
56
57
58-59
Display
*RET
*MODE
*PASS
*Err.01
*Err.05
*Err.06
*Err.07
*Err.08
*Err.13
*Err.22
*SOFT
*E5.LIM
*E6.LIM
*%
*%1
*0%
*100%
*%2
*0%
*100%
*DISP
*USP
Function
Auto return
Mode setup
Passcode
Note # = 0 - 9, where
0 = no passcode
1=111, 2=333, 3=777
4=888, 5=123, 6=957
7=331, 8=546, 9=847
Error setting
E5 limit setting
E6 limit setting
Display mA iin w/w%
Set w/w% for range 1
Set w/w% for range 2
Display resolution
USP setting
Function detail
Auto return to measuring mode Off
Auto return to measuring mode On
Setpoints in maintenance mode Off
Setpoints in maintenance mode On
Maintenance passcode Off
Maintenance passcode On
Commissioning passcode Off
Commissioning passcode On
Service passcode Off
Service passcode On
Polarisation too high
Soft fail
Polarisation too high
Hard fail
Shorted measurement
Soft fail
Shorted measurement
Hard fail
Open measurement
Soft fail
Open measurement
Hard fail
Temperature sensor open
Soft fail
Temperature sensor open
Hard fail
Temp. sensor shorted
Soft fail
Temp. sensor shorted
Hard fail
USP23 limit exceeded
Soft fail
USP23 limit exceeded
Hard fail
Control time-out
Soft fail
Control time-out
Hard fail
LCD + Fail contact
LCD only
Maximum conductivity value
(Minimum resistivity value)
Minimum conductivity value
(Maximum resistivity value)
mA1-range displayed in w/w% off
mA1-range displayed in w/w% on
mA2-range displayed in w/w% off
mA2-range displayed in w/w% on
Press YES to access 0% value adjustm.
Set 0% output value in w/w%
Set 100% output value in w/w%
Press YES to access 0% value adjustm.
Set 0% output value in w/w%
Set 100% output value in w/w%
Auto ranging display
Display fixed to X.XXX
µ
S/cm or M
Ω
•cm
Display fixed to XX.XX
µ
S/cm or M
Ω
•cm
Display fixed to XXX.X
µ
S/cm or M
Ω
•cm
Display fixed to X.XXX mS/cm or k
Ω
•cm
Display fixed to XX.XX mS/cm or k
Ω
•cm
Display fixed to XXX.X mS/cm or k
Ω
•cm
Display fixed to XXXX mS/cm or k
Ω
•cm
Disable the E13 (USP limit exceeded)
Enable the E13 (USP limit exceeded)
Not used
X
0
1
0
1
0
#
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
2
3
4
5
6
7
0
1
Y
0
#
0
1
Z
0
#
Default values
1
On
0
Off
0.0.0
Off
Off
Off
1
Hard
1
Hard
1
Hard
1
Hard
1
Hard
0
Soft
0
Soft
0
LCD/Fail
500
mS
0.002
k
Ω
1.0
µ
S
1.0
M
Ω
0.0
Off
Off
0
Auto
(Con-
ductivity)
2
(Resist-
ivity)
0
Off