69
IM FG410-01EN
4.5 Using Parameter-Variable Waveforms
a) Outputting a parameter-variable waveform
1.
Select the [PWF] parameter-variable
waveform in the [Fctn] field and then
press the
ENTER
ENTER key.
The waveform that is currently set as
the parameter-variable waveform is
output.
Like for other waveforms, the polarity
and amplitude range of the waveform
can also be changed.
b) Changing the waveform of a parameter-variable waveform
1.
When the waveform is set to [PWF]
(parameter-variable waveform), the
[Select] button is displayed to the right
of the polarity/amplitude range icon.
When this button is selected, the
currently selected parameter-variable
waveform name is displayed.
P r e s s t h e
ENTER
E N T E R b u t t o n
to display the parameter-variable
waveform selec-tion screen.
2.
The parameter-variable waveform setting and various parameter settings can be done
in the parameter-variable waveform selection screen. “Oscillator > PWF Select” is
displayed in the top left part of the parameter-variable waveform selection screen.
Waveform polarity/amplitude range
Waveform graph
Applies the changes and
exits the selection screen.
Discards the changes and
exits the selection screen.
Returns the variable
parameter values to
the initial values.
Variable parameters of
waveform
Waveform.
Waveform group
Due to the large number of parameter-variable waveforms, they are categorized into a
number of different groups.
First, select the desired group in the [Group] field.
Next, in the [Waveform] field, set the desired waveform from the various waveforms
listed within the selected group.
Set the polarity and amplitude range of the waveform with the polarity/amplitude range
icon. These settings are done independently for each waveform, and can be changed
even when the selection screen has been exited.
Each waveform has up to 5 specific parameters. Set the desired value for each one of
these parameters.
Select [PWF]
and then press
the ENTER key.
Select the [Select]
button and then
press the ENTER
key.
Set the waveform
to [PWF]
Polarity/amplitude
range icon
When the [Select] button is
selected, the current
parameter-variable waveform
name is displayed.
4.5 Using Parameter-Variable Waveforms
Содержание FG420
Страница 10: ...VIII IM FG410 01EN...
Страница 165: ...151 IM FG410 01EN External dimensions FG410 Unit mm 7 17 General Characteristics...
Страница 166: ...152 IM FG410 01EN 7 SPECIFICATIONS External dimensions FG420 Unit mm...
Страница 167: ...153 IM FG410 01EN RACK MOUNTING DIMENSIONS Inch rack mounting dimensions for 1 unit Unit mm 7 17 General Characteristics...
Страница 168: ...154 IM FG410 01EN 7 SPECIFICATIONS Inch rack mounting dimensions for 2 units Unit mm...
Страница 169: ...155 IM FG410 01EN Millimeter rack mounting dimensions for 1 unit Unit mm 7 17 General Characteristics...
Страница 170: ...156 IM FG410 01EN 7 SPECIFICATIONS Millimeter rack mounting dimensions for 2 units Unit mm...
Страница 171: ...157 IM FG410 01EN 7 17 General Characteristics...