26
IM FG410-01EN
4. BASIC OPERATION
4.1.2 Restoration of settings at power-on
When the power is switched on/off with the power switch, the settings before the previous time the
power was switched off are restored when the power is switched on again.
The output on/off settings at power-on can be set on the Utility screen.
However, if the power supply to the equipment is directly cut off while the equipment's power is on,
the settings are set to the contents of setting memory 1 when the equipment is powered on again.
a) Restoration of settings when power switch is switched on/off while power supply is
connected
The most general case is illustrated below.
Power supply connected
Settings
AAA
LINE
Power supply disconnected
The power remains off
Power supply
reconnected
LINE
LINE
The power remains off
(standby state)
Power supply connected
LINE
The power is switched on
(former settings are restored)
Power supply connected
1
LINE
The power is switched off
(standby state)
2
1
2
Press the power switch.
Even if the
power supply is
disconnected in
the power off
state, this has
no influence on
the next restore
operation.
Power on state
Press the power switch.
Settings
AAA
While the equipment power is off, even if the power supply is cut off due to the disconnection of the
cord or the shutoff of a connected breaker, this has no influence on the restore operation the next time
the equipment is powered on again.
Содержание FG420
Страница 10: ...VIII IM FG410 01EN...
Страница 165: ...151 IM FG410 01EN External dimensions FG410 Unit mm 7 17 General Characteristics...
Страница 166: ...152 IM FG410 01EN 7 SPECIFICATIONS External dimensions FG420 Unit mm...
Страница 167: ...153 IM FG410 01EN RACK MOUNTING DIMENSIONS Inch rack mounting dimensions for 1 unit Unit mm 7 17 General Characteristics...
Страница 168: ...154 IM FG410 01EN 7 SPECIFICATIONS Inch rack mounting dimensions for 2 units Unit mm...
Страница 169: ...155 IM FG410 01EN Millimeter rack mounting dimensions for 1 unit Unit mm 7 17 General Characteristics...
Страница 170: ...156 IM FG410 01EN 7 SPECIFICATIONS Millimeter rack mounting dimensions for 2 units Unit mm...
Страница 171: ...157 IM FG410 01EN 7 17 General Characteristics...
Страница 173: ...159 IM FG410 01JA...
Страница 178: ......
Страница 179: ......