6.1 Arbitrary Wave Edit Software Error
6.1 Arbitrary Wave Edit Software Error
The following table summarizes the error specifications of the
Arbitrary Waveform Editor
.
Table 6-1 Error Messages
Message
Description
Memory Allocation Failed.
Memory for OS operation could not be secured at startup.
No Spline point.
During waveform generation using interpolation, the
interpolation was performed without any control points
specified.
Cannot create two spline point on same X.
Do you want continue?
Displayed when the leftmost and rightmost values of the Y
axis are different when generating a waveform using
interpolation.
File Write error.
An error occurred while a file was being saved in “ARB
Edit”. If this error persists, restart the “ARB Edit”.
File Read error
An error occurred while a file was being read in the “ARB
Edit”. Do not use this file.
Read in is interrupted because the data file
contains data of a model that is not supported.
An error occurred because a data file containing the
information of a model other than the FG410/FG420 was
read. Do not use this file.
Clip Board Open error.
An error occurred during an inter-waveform operation
executed for the clipboard. If this error persists, restart the
“ARB Edit”.
Clip Board Read error.
Clip Board Write error.
Clip Board error.
Constant format error.
An arbitrary function expression for waveform generation
contains an error.
Modify the error cause according to the message.
Syntax error in equation.
Lack of parenthesis.
Unbalance of parenthesis.
Divided by 0.
Compile error.
The unit of the axis was changed.
Indicates that the axis setting is other than the initial state,
when the PWF screen is displayed.
The axis range was set to X[0.0 - 1.0], Y[
−
1.0 -
1.0].
Illegal Font Size.
Modify the specified font size in the printing dialog box.
No Listeners on the INTERFACE.
This error occurs when waveform data transfer, read, or
oscillator settings are performed with no signal generator
connected via USB.
The Sequence Edit Software is running.
Terminate the Sequence Edit Software and
restart.
After terminating the
Sequence Edit Software
, start the
Arbitrary Waveform Editor
.
Transfer is interrupted because an error
occurred.
If the “-225, ‘Out of memory’” message is displayed
immediately before this message, check the total size of the
FG410/FG420 arbitrary waveform data and delete any
unnecessary data.
If such a message is not displayed, switch off the power of
the FG410/FG410 once before operating again.
IM FG410-61EN
6-2
Содержание FG410
Страница 1: ...User s Manual FG410 FG420 ARBITRARY WAVEFORM EDITOR IM FG410 61EN 3rd Edition ...
Страница 3: ......
Страница 10: ...1 OVERVIEW 1 1 General 1 2 1 2 Function Tree 1 2 1 3 Conventions 1 5 ARB Edit 1 1 ...
Страница 15: ...1 3 Conventions IM FG410 61EN 1 6 ...
Страница 44: ...4 7 Copy and Paste IM FG410 61EN 4 15 ...
Страница 45: ......
Страница 76: ...6 ERROR MESSAGES 6 1 Arbitrary Wave Edit Software Error 6 2 IM FG410 61EN 6 1 ...
Страница 80: ......
Страница 82: ......
Страница 83: ...https www yokogawa com ymi Yokogawa Test Measurement Corporation ...