17-7
IM 701730-01E
Specifications
17
Data Storage
Item
Description
History memory
When interleave is ON:
Automatically save up to 2048 acquisition data points.
When interleave mode is OFF:
Automatically save up to 1024 acquisition data points.
Floppy disk
1
or PC card, network drive
2
, USB storage
Saves setup data, waveform data, and various data
1. Select floppy disk drive or PC card interface for the built-in media drive.
2. When the Ethernet interface option is installed
Other
Item
Description
Initialization
Resets settings to the factory default (excluding date/time setting, communication interface
settings, settings stored to the internal memory using the store/recall function, and language
setting)
Auto setup
Automatically sets the optimum voltage axis, time axis, trigger, and other settings for the input
signal.
Store/Recall
Store and recall up to three sets of arbitrary setup data to and from the instrument’s internal
memory.
Preset
Presets for CMOS (5 V), CMOS (3.3 V), ECL, and user settings.
Action-on-trigger
Outputs screen image data, saves waveform data, activates buzzer notification, or sends email
messages each time a trigger occurs.
Mail transmission
1
Periodically sends the status of the instrument to a specified mail address via the Ethernet
network. Can also send information as an action for GO/NO-GO determination and action on-
trigger.
Calibration
Auto calibration and manual calibration available.
Deskew
Corrects the delay of the acquired waveforms on each channel.
Adjustment range is
±
100 ns (0.01 ns resolution)
Environment settings
Set the screen color, date/time, message language, and click sound ON/OFF
Probe compensation signal output
Outputs a signal (rectangular signal of approx. 1 Vp-p and approx. 1 kHz) from the probe
compensation output terminal on the front panel
Overview
Check the system status of the instrument.
Self test
Memory test, key test, printer test, floppy disk drive test, PC card test, and accuracy test are
possible.
Menu language setting
Menus can be displayed in English or Chinese.
Help function
Displays help concerning the settings (select Japanese, English, Chinese, or Korean
2
)
Thumbnail
Shows thumbnails of the screen image data
1. When the Ethernet interface option is installed
2. Korean can be selected on products with firmware version 2.09 or later.
17.5 Functions