INST
ALLER'S
INSTRUCTION
INST
ALLER'S
INSTRUCTION
P29 OF 44
CONNECT REFRIGERANT PIPES BETWEEN INDOOR AND OUTDOOR UNITS
P30 OF 44
INLTS
STRT COUP
COUP-H
OFST
O
ELBF90
O
ELBF45
SOFT
TEE ENDF
RDER
INSTALLATION OF ACCESSORIES
CONNECT REFRIGERANT PIPES
* Use factory-recommended components, as briefly illustrated below.
* Cover line set in a sequence, either from indoor to outdoor, or the other way.
* Secure line set covers onto the wall using factory-recommended accessories.
Not to damage line sets.
Seal Copper Line Set/Wire Cable/Drain Hose Line Combination:
LINE SET COVERS
OUTDOOR UNIT FOOT RISER OR BRACKETS
A
B
A
B
C
D
A
B
Pipe insulation
Interconnection cable
Sealing tape
Cable tie
Sealing tape
Interconnection cable
Drain hose
Pipe
Refrigerant pipe
Hanger or
Clamp
Pipe
Interconnection cable
Cable tie
Wall
Outside
Pipe/wire wall
sleeve/ring
Putty (stuffing gaps)
Overlap wrapping
tape..
Pipe of indoor unit
Connecting pipe
Seal Copper Line Set/Wire Cable/Drain Hose Line Combination
* Run cables along with the refrigerating copper line sets and secure them with tapes at 6 feet apart.
* Wrap tape closely (cover a third of the width of the wrapping tape applied early) to ensure good sealing.
* Tape and seal the end of wrapping tape.
* Shape the pipe combination gently, without causing kinking, sharp bending, or other damage to it.
* Fix the pipe combination securely on the external wall with proper clamps, at 6 feet apart.
* Fill the gap between the wall hole and wall sleeve with putty to keep from rain or dust entering inside.
PIPING GUIDE
Set the packed pipes
vertically and then unwind
slowly.
Don't unwind only one end
of the coiled pipes.
Use pulley to keep the safe
bending radius..
May also use rolling wheel to
reduce internal pipe tension
and avoid possible
deformation.
Use elbow tool to keep
bending radius.
Keep minimum bending
radius..
Don't make sharp or small
radius bending.
Don't bend too long of a
pipe without tools.
Don't make less than 90
degree bend.
Do not make to sharp of a
bend.
Inside
Unit front panel
Model
BRKT-0918-SC1
BRKT
-SC1
-1860
A
B
LBs
Btu/h
Capacity
Size(Inch)
17.7
21.7
15.4
18.3
320
360
09K-18K
18K-60K
* Made of stainless steel.
Model
BRKT-0918-ST1
BRKT
-ST1
-1860
A
B
LBs
Btu/h
Capacity
Size(Inch)
17.7
21.7
15.4
18.3
320
360
09K-18K
18K-60K
Model
RIST-0918-PVC
RIST-1860-PVC
A
B
C
LBs
Btu/h
Capacity
Size(Inch)
14.2
17.7
3.7
3.1
3.7
3.1
220
260
09K-18K
18K-60K
D
4.1
4.1
RIST-XXXX-PVC
Foot Riser
Accessories: End Caps (Optional)
* Shock-proof PVC, Weatherproof & UV resistant.
* Supplied with fastening screws and anchor bolts.
* Easy to install.
* The "honeycomb" structure acts as an anti-vibration
& humming absorption for a quite operation.
* Made of steel.
* Coated with weatherproof polyester powder.
BRKT-XXXX-SC1
BRKT-XXXX-ST1
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !