![YMGI WMMS-09K-V2A(57)2 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/ymgi/wmms-09k-v2a-57-2/wmms-09k-v2a-57-2_installation-instructions-manual_3574145008.webp)
BRIEF UNIT INFO
BRIEF UNIT INFO
P13 OF 44
P14 OF 44
ILLUSTRATION OF INSTALLED SYSTEM SAMPLE
Notes: Actual unit/ part appearance and installation may vary from the illustrated.
Subject to continuous improvement and change without notice.
Mini Split Wall Mount Systems are designed for high performance, easy installation and service. Each system
consists of one or several indoor units and one outdoor unit, which are connected by one set or several multiple
sets of interconnection refrigerant pipes and electric wires.
As shown in the following sample picture of outdoor unit, air is drawn through the coil from the rear side and then
discharged from the front side. In cooling mode, air passing through coil is heated; in heating mode, air passing
through coil is cooled.
Sample Wall Mount Mini Split System (For Continuous Engineering Improvement and Various Marketing
Needs and Actual Part Availability Reason, Unit Appearance Subject to Change or Update Continuously
without Prior Notice)
Outdoor unit(s) provides the electrical and thermal power for the whole system. Electrical and thermal
components such as compressors and motors and heat exchange coils and others, are incorporated into the
cabinet in an optimized order. They can be either hung on the wall or installed on the ground. Once stacking or
bracket kit is used, some outdoor units can be stacked 2 or 3 units high, upon unit size and applications. Air is
discharged horizontally, quietly and smoothly. These units are a perfect fit in locations where installation and
applications of general up-flow condensing units are limited, such as apartments, condos, lofts, multi-families and
high-rise buildings and others named or unnamed.
Indoor unit(s) delivers the thermal and acoustical comfort to the rooms. Air is drawn through the coil from the
front or topside and then discharged from the bottom. In cooling mode, air passing through coil is cooled; in
heating mode, air passing through coil is heated. Air is filtered or treated by the built in mechanism (washable or
enzyme equipped or electrostatic powered filter, varies from model to model), before being delivered into the
room, with more than enough comfort and care, at a wide angle (swing or not, varies from model to model).
NOTES: Since ductless system is not designed to incorporate or use with ducted return or discharge
tunnels, one single-zone unit SHALL NOT be used to take care of the cooling or heating load of more
than one-story room. Several single-zone ductless systems or multiple-zone ductless systems shall be
proper in this regard.
These units are designed for applications at:
* Residential
* Light commercial
* Commercial
* Hospital
* Institutional
* Industrial
Apartments
Hotels
Homes
Application Samples of Wall Mount Mini Split Systems
Air In
Air Out
BRIEF INTRODUCTION TO MINI SPLIT WALL MOUNT SYSTEM
Air In
Air Out
Outdoor unit
Indoor unit
Air out
Drainage hose
Connection pipe
Disconnect Box
To correctly sized
HVAC CIRCUIT
BREAKER
Indoor unit
Outdoor unit
Display icon (May vary open models):
Air wall sleeve
Guide panel
Filter
Bolt
Nut
Wrench
Pipe/wire
wall sleeve
Digital
display
Lineset PVC cover
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !