TROUBLE SHOOTING

P35 OF 44

TROUBLE SHOOTING

P36 OF 44

Cooling, dehumidifying: compressor 
stops running, indoor fan motor 
works. Heating: all will stop running.

The circuit on API has malfunction, 
replace the outdoor unit API.

Whole unit's
current testing
malfunction

Off 3s
blink 13
times

U5

☆ ■

Cooling, dehumidifying: compressor 
stops running, indoor fan motor 
works. Heating: all will stop running.

Please refer to troubleshooting (IPM 
protection, compressor lose steps, 
compressor current overcorrect 
protection).

P5

Off 3s
blink 15
times

Compressor
current 
overcorrect
protection

□ ☆ □ □

Under the heating mode, 
compressor running, indoor/outdoor 
fan motor stop working

It is normal function

H1

H2

Off 3s
blink 
once

Off 3s
blink 
twice

Defrosting

Electrostatic 
dedust
protection

Cooling, dehumidifying; compressor 
stops running, indoor fan motor 
works. Heating: all will stop running

1) Wire terminal OVC-COMP loosen 
    or circuit, has problem, the 
    resistance of SAT should be lower 
    than l ohm.
2) Please refer to troubleshooting
    (exhaust/overload protection)

H3

Off 3s
blink 3
times

Compressor
overload
protection

18

19

20

21

22

□ ☆

Pls refer to troubleshooting

H4

H5

Off 3s
blink 4
times

Off 3s
blink 5
times

System
abnormal

IPM protection

Cooling, dehumidifying; compressor 
stops running, indoor fan motor 
works. Heating: all will stop running

Pls refer to troubleshooting

Cooling, dehumidifying; compressor 
stops running, indoor fan motor 
works. Heating: all will stop running

23

24

■ □ ■

Overload normal works, compressor 
running, frequency declines.

Pls refer to troubleshooting.

Pls refer to troubleshooting.

Replace the outdoor control board 
API.

Replace the outdoor control board 
API.

Replace the outdoor control board 
API.

Pls refer to Part 3 capacitor charging
fault of troubleshooting.

To check whether the ambient 
Temp. of IPM is too high or the heat-
sinhing of IPM is dirty else replace 
the outdoor baord API.

HC

H7

H0

Lc

U1

EE

PU

P7

P8

Off 3s
blink 6
times

Off 3s
blink 7
times

Off 3s
blink 10
times

Off 3s
blink 11
times

Off 3s
blink 13
times

Off 3s
blink 15
times

Off 3s
blink 17
times

Off 3s
blink 18
times

Off 3s
blink 19
times

PFC prtection

Compressor
lose steps

Heating, anti-
high temp. 
declines

Starts up fail

Compressor
current testing
circuit 
malfunction

EEPROM
malfunction

Capacitor
charge
malfunction

Module sensor
circuit diagram

Module
temp.
over high
protection

Cooling, dehumidifying: compressor 
stops running, indoor fan motor 
works. Heating: all will stop running.

Pls refer to troubleshooting.

Pls refer to troubleshooting.

Cooling, dehumidifying: compressor 
stops running, indoor fan motor 
works. Heating: all will stop running.

Cooling, dehumidifying: compressor 
stops running, indoor fan motor 
works. Heating: all will stop running.

Cooling, dehumidifying: compressor 
stops running, indoor fan motor 
works. Heating: all will stop running.

Cooling, dehumidifying: compressor 
stops running, indoor fan motor 
works. Heating: all will stop running.

Cooling, dehumidifying: compressor 
stops running, indoor fan motor 
works. Heating: all will stop running.

Cooling, dehumidifying: compressor 
stops running, indoor fan motor 
works. Heating: all will stop running.

25

26

27

28

29

30

31

32

33

34

35

DC Bus 
voltage dips

U3

off 3s 
blink 20 
times

cooling, dehumidifying: compressor 
will stop, indoor fan motor works, 
Heating: all will stop.

Power voltage is not staable.

cooling, dehumidifying: compressor 
will stop, indoor fan motor works, 
Heating: all will stop.

1) Check the Input voltage if the 
    Voltage is lower than 150VAC, 
    restart the machine when the 
    power supply is normal.
2) Checking the reactor L 
    connection.

off 3s 
blink 21 
times

PL

Low DC Bus 
voltage 
protection

□ ■

□ ☆ ■ ☆

☆ □

■ □

□ □ □ ■

□ ■

□ □ ■ ☆

Outdoor temp. sensor hasn' t 
connected well, or damaged, 
please refer to the sensor resistance
value for checking.

Cooling, dehumidifying: compressor 
will stop, indoor fan motor will work. 
Heating: all will stop.

Off 3s 
blink 
18 
times

Outdoor 
condensor
sensor open 
circuit, short 
circuit 

12

13

14

15

16

☆ □

F4

Cooling, dehumidifying: after running 
for 3mins later, the compressor will
stop to run, indoor fan motor will 
start to run. Heating: after run 3mins
later, all will stop to run.

1) Exhaust temp sensor hasn' t 
    connected well, or damaged, 
    please refer to the sensor ;
    resistance value for checking.
2) Sensor head hasn' t insert into 
    the copper tube.

Off 3s 
blink 

times

F5

Outdoor air
exhaust 
sensor
open circuit,
short circuit

Please refer to troubleshooting

1) Input power supply is too low;
2) System voltage is too high, 
    overload is too much.

Overload normal operation, 
compressor is running, frequency
descending.

Overload normal operation, 
compressor is running, frequency
descending.

Off 3s 
blink 
6 times

Off 3s 
blink 
8 times

F8

F6

Overload limit/
descending
frequency

Over current
need 
frequency
descending

1) Overload is too much, ambient 
    temp. is too high;
2) Refrigerant is short;
3) Electric expansion malfunction.

Overload normal operation, 
compressor is running, frequency
descending.

Off 3s 
blink 
9 times

F9

Air exhaust
over high
need frequency
descending

■ □ ■

■ ■

17

1) Testing wire terminal L and N 
    position If higher than 265VAC,
    please cut off the power supply
    and restart until back to normal;
2) If input voltage is normal, testing
    the voltage of electrolytic 
    capacitor on API after turn on the 
    unit. There may be some problem 
    and replace the API if the 
    electrolytic capacitor voltage 
    range at 200-280V.

Cooling, dehumidifying, compressor 
stop running fan motor works.
Heating: all will stop.

Off 3s 
Blink 
11
times

PH

DC generatrix
voltage
is too high

Outdoor room temp. sensor hasn' t 
connected well, or damaged, please 
refer to the sensor resistance value 
for checking.

Cooling, dehumidifying: compressor 
will stop, indoor fan motor will work. 
Heating: all will stop.

Off 3s 
blink 
three 
times

F3

Outdoor 
ambient
sensor circuit 
open, circuit 
short

☆ ■

11

36

Overload normal works, compressor 
running frequency declines.

Whole unit break for 30mins and 
discharge, to check the outdoor 
control board API's IPM module 
coolant whether is short, the radiator 
is tightened. If above phenomenon 
is not ok, please improve or replace 
the control board API.

EU

IPM temp. is 
too high limit/
decrease 
frequency

37

Four-way 
valve 
abnormal

U7

This malfunction happened, only in 
heating mode, all will stop to run.

1) Power supply voltage is lower 
    than AC175V.
2) Wire terminal 4V loosen or wire 
    break.
3) 4V damaged, replace 4V.

38

39

☆ □

U9

Outdoor unit 
zero-cross 
detecting error

Cooling: compressor will stop, 
indoor fan motor works. 
Heating: all will stop.

Replace the outdoor control board 
APl.

Anti-freezing 
limit/decrease
frequency

All loads work normally but the 
running frequency limited or 
decrease.

FH

■ ■

Indoor unit air return is poor or fan 
speed is too low.

Notes:

Subject to continuous engineering change and product improvement without notice.

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Содержание WMMS-09K-V2A(57)2

Страница 1: ...in material and workmanship for normal use and maintenance Installation operation maintenance and service shall follow professional practices for regular cooling and heating equipment NEC State City...

Страница 2: ...etails may vary and some may be the key to determine the success and quality of the installation Experience with certain manufacturer may not be applied fully to another manufacturer For example wirin...

Страница 3: ...s and wires are to be installed 11 If all the suggestions have been taken and all the necessary steps are followed CUSTOMER AND TECHNICIAN MUST READ The cost of not having your unit installed properly...

Страница 4: ...rical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to outdoor unit 9 The size of HVAC c...

Страница 5: ...rience or professional knowledge to correct the problem RECEIVING AND FREIGHT DAMAGE ATTENTION Freight package unit shall be checked thoroughly for damage at receiving before accepting by signing on t...

Страница 6: ...help you in the following steps in sequence from 1 to 3 CUSTOMER AND TECHNICIAN MUST READ If the damage is minor or partial that you choose to accept you can contact the distributor or YMGI to discus...

Страница 7: ...Customer Request to Ship Products to YMGI Service Center for Inspection and Repair and Authorization to Charge form 2 You will review the form and fill all fields appropriately sign and send back to t...

Страница 8: ...ons of general up flow condensing units are limited such as apartments condos lofts multi families and high rise buildings and others named or unnamed Indoor unit s delivers the thermal and acoustical...

Страница 9: ...6 7 25 3 5 3 6 7 x 30 1 8 18 Cooling Speed SH H M L RPM 1300 1100 900 700 1350 1150 950 750 1400 1150 1000 850 1350 1150 1000 850 19 Heating Speed SH H M L RPM 1300 1140 980 820 1350 1190 1020 850 145...

Страница 10: ...s can be installed on a wall or balcony close to the indoor unit the following are some benefits for contractors and customers Each system is thoroughly tested before leaving the factory Each unit is...

Страница 11: ...27 6 37 9 37 6 Model 09K 12K 18K 24K Unit W 30 30 35 0 35 0 D1 12 6 21 3 11 3 12 6 21 3 11 3 15 6 22 0 22 0 14 3 14 3 15 6 D 10 1 10 1 13 4 13 4 P20 OF 44 USER NOTES AND SERVICE LOG 6 6 12 100 6 20 12...

Страница 12: ...Tape Level Flash Light Screw Driver Phillps and Flat Hammer Knife Scissors Goggled Glass Mask Gloves Ladder 2 Refrigeration Related Work RECOMMENDED TOOLS FOR INSTALLATION 3 Electrical Related Instal...

Страница 13: ...ors are to be used make sure to keep the two holes close to each other at least 2 inches apart Mounting plate should be attached to the structural part of the wall Minimum clearance as shown below is...

Страница 14: ...in condensing unit othewise condensate may ice up causing damage to the condensing unit Suggest to use YMGI provided brackets and condensate drainage fitting accessories Indoor unit front Bottom the r...

Страница 15: ...perpendicular to the pipe surface Don t cut too fast or too hard Turn and tighten the tube cutter slowly Remove residual left and de bur at the cutting edge The cutting edge should be clear and clean...

Страница 16: ...ation securely on the external wall with proper clamps at 6 feet apart Fill the gap between the wall hole and wall sleeve with putty to keep from rain or dust entering inside PIPING GUIDE Set the pack...

Страница 17: ...frigerant Charge Level Reference Temperature Pressure Table Split Condensing Unit R410A AC Product Series YMGI Group Mini Split Version 01 11 2010 Reference Temperature Pressure Table Split Condensing...

Страница 18: ...ng indoor fan motor works Heating all stop running 3s off blink four times 1 Forcibly lift up the panel at a specific angle from the two ends of the front panel following the arrow direction Then pull...

Страница 19: ...e is not staable cooling dehumidifying compressor will stop indoor fan motor works Heating all will stop 1 Check the Input voltage if the Voltage is lower than 150VAC restart the machine when the powe...

Страница 20: ...protection Heating LED Off 3S Blinks 6 times HE Compressor de managet protection rotor locked doesn t rotate Heating LED Off 3S Blinks 14 times L0 Airflow switch error TBD L1 Humidity sensor error TB...

Страница 21: ...uring gas sensor error Running LED Off 3S Blinks 21 times HP Solar AC solar power input voltage is higher than 180V TBD dA AHU or RT discharge air relative humidity sensor error TBD dE AHU or RT fresh...

Страница 22: ...r Cooling LED Off 3S Blinks 7 times FC Slide door error or air louver mechanism error TBD FE Over load sensor error TBD H8 Water level high overflow protection Heating LED Off 3S Blinks 8 times H9 Ele...

Страница 23: ...the unit and or know more details than anybody else They will check the unit and find out the problems with the professional knowledge about HVAC and electric product installation by using special to...

Отзывы: