* To be installed at the position where the air
delivered from the unit can reach every comer of
the room.
* To avoid being affected by the outdoor air.
* To avoid blockage to the air inlet or outlet of the unit.
* To avoid too much oil, smoke or steam.
* To avoid possible generation, inflow, lingering or
leakage of flammable gases.
* To avoid high-frequency facilities (such as high
frequency arc welders, etc.).
* To avoid the places where acid solutions are
frequently used.
* To avoid the places where some special sprayers
(sulfides) are frequently used.
* Not to install on top of the musical instruments, TV,
computer etc. valuable appliance.
* Not to install a fire alarming device near the air
outlet of the unit (during operation, the fire alarm
device might be erroneously triggered by the warm
air from the unit).
All Units Shall Be Installed by Licensed Contractor or Technician.
Read Manuals before Installation.
Check the unit for damage and missed parts or accessories. If damage is found or parts are found missing, call
the distributor right away.
Spin fan wheels and blades to check and make sure they can rotate freely. If fan wheel scratches with housing,
call the distributor right away and do not to proceed with the installation before it is fixed.
Check the unit to make sure no foreign materials have been left in the unit.
Check all the parts and accessories that are needed other than those provided with the unit.
It is strongly recommended to only use YMGI supplied or recommended parts and accessories.
Be sure a properly sized circuit breaker is for the electric power to the units.
Pre-build the support platform on the ground or bracket for the wall before or during construction and before
installation. Refer to the table below for footprint dimensions.
Read installation instructions of all units thoroughly.
Ask rep./distributor/us anything you are not sure about.
Get your tools and parts ready for installation.
CAUTION & SUGGESTIONS TO FOLLOW PRIOR TO INSTALLATION
* Either the indoor unit or the outdoor unit can be
higher, but the height difference must comply the
stated requirements.
* Try to reduce the bending of the piping line as much
as possible so as to avoid possible negative impacts
upon the performances of the units.
* Make P-trap if elevation drop difference is more
than 25", as illustrated below.
Indoor unit
Outdoor unit
Lift
Indoor unit
Outdoor unit
Drop
Oil-Trap
≤
18 Ft
Locate the central hole at the stud (firn structure)
At least 6"
6" or more
from sidewall
Respect the slope
Plumb
Mounting Plate
Anchors of self-
tappping screw
6" or
more from
sidewall
Install Mounting Plate and Drill Hole for Combination of Copper Line/Wire Cable/Drain Hose
NOTES:
Anchors must be put into the holes, where the solid
arrows are pointing, as shown above, to secure the
mounting plate firmly and to hold the weight of indoor
unit. If more screws/anchors are to be used, make
sure to keep the two holes close to each other, at
least 2 inches apart.
Mounting plate should be attached to the structural
part of the wall. Minimum clearance, as shown below,
is required in order to ensure proper airflow and
enough service room.
INSTALL WALL MOUNT PLATE
* Check unit to make sure the unit is in good shape and ready to install.
* Check unit to make sure the installation location is firm enough to hold the weight of the whole unit and is
convenient to install, maintain, and service.
* Install Indoor unit. Enough anchor bolts/nuts shall be used to secure mounting plates for indoor units.
Brackets should be at level position.
Mark drill positions. At least 4 anchor holes, one at each perimeter corner of the plate are needed to secure the
plate, where the bold arrows are pointing, as shown in the picture above. Refer to the specification sheet for
unit weight so that enough anchors are installed at proper positions.
Pre-drill guiding holes where are marked for anchors or screws on the wall
Confirm the position of the holes and finish drill to the depth needed for anchors (NOT for screws)
Align mounting plate holes with those holes drilled on the wall and put anchors or screws into the holes to
secure mounting plate.
STEPS TO MOUNT PLATE:
a
b
c
Drill mounting holes
to make sure at least
either one of three
dimensions a, b and
c is 16" center to
center.
INSTALLATION-INDOOR UNIT
INSTALLATION POSITIONS FOR OUTDOOR UNIT
INSTALLATION LOCATIONS & CAUTIONS
If pipes need to come out of the right side (facing
the front of indoor unit) of the indoor unit, snap off
portion
《
1
》
on plastic casing.
If pipes need to come out of the bottom side
(facing the front of indoor unit) of the indoor unit,
snap off portion
《
2
》
on plastic casing.
If pipes need to come out of the left side (facing
the front of indoor unit) of the indoor unit, snap off
portion
《
3
》
on plastic casing.
DRILL 3IN HOLE FOR PIPING/WIRING/DRAIN
Locate the center where the hole will need to
drilled.
Drill the holes of 2.5-3Inch diameter. A down pitch
about 1/4" per foot, as illustrated below, is needed
for the hole, in order to drain the condensate
properly.
PREPARE INDOOR UNIT- COPPER LINE SET/DRAIN HOSE
《
1
》
《 》
2
《 》
3
INST
ALLER'S
INSTRUCTION
INST
ALLER'S
INSTRUCTION
P23 OF 44
P24 OF 44
* The location and structure shall also be convenient for both installation and service.
* The location shall NOT be where discharge air and noise could bother your neighbor.
* The location shall NOT be somewhere drain may cause any damage to property or bother the neighbor.
* The location shall NOT be somewhere soldering or torching work may cause fire or smoke to the materials around.
* The location shall NOT be somewhere near flammable gases.
* The location shall NOT be in or close to corrosive gases.
* The location shall NOT be somewhere children can access.
Hole Diameter: 2.5~3 In
Align ruler
with straight
line