Error
Code

Description

Indoor Unit LED Display

C1

Current arch protection

Running LED-Off 3S, Blinks 12 times

C2

Current leakage protection

Running LED-Off 3S, Blinks 13 times

C3

Mis-wiring protection

Running LED-Off 3S, Blinks 14 times

C5

Jumper error protection

Running LED-Off 3S, Blinks 15 times

C6

No-ground

Running LED-Off 3S, Blinks 16 times

Cd

Too much CO2 protection

TBD

CF

Current short-cut protection

TBD (Buzzer will sound once every 2 sec.)

d1

WSHP: UV light error

TBD

E0

Commercial: Water pump overload/error/flow switch error

Running LED-Off 3S, Blinks 10 times

E1

System high pressure protection

Running LED-Off 3S, Blinks 1 time

E2

Anti-freezing protection (heat exchanger-ID, OD)

Running LED-Off 3S, Blinks 2 times

E3

Low pressure protection (run cooling when OD is too cold)

Running LED-Off 3S, Blinks 3 times

E4

Compressor dischage pressure too high

Running LED-Off 3S, Blinks 4 times

E5

System/compressor current too high

Running LED-Off 3S, Blinks 5 times

E6

Communication error (ID-OD)

Running LED-Off 3S, Blinks 6 times

E7

Mode clash (some ID runs cooling/fan, some runs heating

Running LED-Off 3S, Blinks 7 times

EA

VRF: Oil valve protection

TBD

Ec

Commercial & VRF: Water flow protection (lack of water flow)

TBD

Ed

System temperature too high

TBD

EE

Memory chip error (U5)

Heating LCD-Off 3S, Blinks 15 times

EF

Outdoor fan motor overload

TBD

EL

Fire alarm

TBD

EP

Shell top high temperature protection

TBD

F0

System refrigerant lack or restriction protection

Cooling LED-Off 3S, Blinks 10 times

F3

Outdoor abmient temperature sensor error

Cooling LED-Off 3S, Blinks 3 times

F8

Incoming water temperature sensor error

Cooling LED-Off 3S, Blinks 8 times

F9

Outgoing water temperature sensor error

Cooling LED-Off 3S, Blinks 9 times

FA

Oil temperature sensor error

TBD

Fd

Suction gas temperature sensor error

TBD

FE

User side water sensor error

TBD

FL

Water tank-middle sensor error

TBD

FP

CO2 checking error

TBD

FU

Shell top temperature sensor error protection

TBD

H1

Heating-Defrosting, or oil return

TBD

H2

Static electric de-dust protection

Heating LED-Off 3S, Blinks 2 times

H3

Compressor over-temperature protection

Heating LED-Off 3S, Blinks 3 times

H4

System abnormal (many different other reasons…)

Heating LED-Off 3S, Blinks 4 times

H5

IPM abnormal / Control M odule Protection

Heating LED-Off 3S, Blinks 5 times

H6

Indoor fan motor-no feedback

Running LED-Off 3S, Blinks 11 times

H7

Comopressor loses steps, not being able to check rotor position

Heating LED-Off 3S, Blinks 7 times

HC

PFC board abnormal / PFC protection

Heating LED-Off 3S, Blinks 6 times

HE

Compressor de-managet protection (rotor locked /doesn't rotate)

Heating LED-Off 3S, Blinks 14 times

L0

Airflow switch error

TBD

L1

Humidity sensor error

TBD

L2

Water level switch error / hot water tank level switch error

TBD

L3

Outdoor DC motor error (L3 for dual -mtor 1, LA for motor 2)

Running LED-Off 3S, Blinks 23 times

L4

Filter clogged

TBD

L5

Circulating water temperature sensor error

TBD

L6

System capacity insufficient

TBD

L7

Water pressure switch protection

TBD

Lc

Starting failure

Heating LED-Off 3S, Blinks 11 times

Ld

Power phase loss/lack

TBD

LE

Compressor locked

Running LED-Off 3S, Blinks 22 times

LF

Compressor over-speed protection

TBD

LH

Indoor ambient temperature too high

TBD

LL

Indoor ambient temperature too low

TBD

LP

Indoor-Outdoor units don't match or power line connection error

Running LED-Off 3S, Blinks 19 times

P0

Driving module resumed

TBD

P5

Driving board checking-compressor current too high

Heating LED-Off 3S, Blinks 15 times

P6

Driving board checking-communication error with indoor board

Heating LED-Off 3S, Blinks 16 times

P7

Radiator loose, or IPM /PFC board sensor abnormal /error

Heating LED-Off 3S, Blinks 18 times

P8

Radiator loose, or IPM  /PFC board too hot

Heating LED-Off 3S, Blinks 19 times

P9

AC contactor protection

TBD

PA

AC current protection (incoming)

TBD

Pc

Current checking-circuit error or current sensor error

TBD

P37 OF 44

P38 OF 44

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

ERROR AND PROTECTION CODE SUMMARY

ERROR AND PROTECTION CODE SUMMARY

Notes

:

1.Some codes are not malfunctions and will not require you to do anything, since the unit will resume normal 
   functions once the unit finishes its designated work such as defrost, oil return...
2.Some other codes denote malfunctions and the unit will not resume normal functions until your technician 
   checks your unit and fixes the problems such as dirty coils, clogged filters, bad control boards...You can 
   have your technician to call 866-833-3138 for help of  technical support and trouble-shoot.

Notes

:

1.Some codes are not malfunctions and will not require you to do anything, since the unit will resume normal 
   functions once the unit finishes its designated work such as defrost, oil return...
2.Some other codes denote malfunctions and the unit will not resume normal functions until your technician 
   checks your unit and fixes the problems such as dirty coils, clogged filters, bad control boards...You can 
   have your technician to call 866-833-3138 for help of  technical support and trouble-shoot.

UNIT MAINTENANCE & 

SER

VICE GUIDE

UNIT MAINTENANCE & 

SER

VICE GUIDE

Содержание WMMS-09K-V2A(57)2

Страница 1: ...in material and workmanship for normal use and maintenance Installation operation maintenance and service shall follow professional practices for regular cooling and heating equipment NEC State City...

Страница 2: ...etails may vary and some may be the key to determine the success and quality of the installation Experience with certain manufacturer may not be applied fully to another manufacturer For example wirin...

Страница 3: ...s and wires are to be installed 11 If all the suggestions have been taken and all the necessary steps are followed CUSTOMER AND TECHNICIAN MUST READ The cost of not having your unit installed properly...

Страница 4: ...rical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to outdoor unit 9 The size of HVAC c...

Страница 5: ...rience or professional knowledge to correct the problem RECEIVING AND FREIGHT DAMAGE ATTENTION Freight package unit shall be checked thoroughly for damage at receiving before accepting by signing on t...

Страница 6: ...help you in the following steps in sequence from 1 to 3 CUSTOMER AND TECHNICIAN MUST READ If the damage is minor or partial that you choose to accept you can contact the distributor or YMGI to discus...

Страница 7: ...Customer Request to Ship Products to YMGI Service Center for Inspection and Repair and Authorization to Charge form 2 You will review the form and fill all fields appropriately sign and send back to t...

Страница 8: ...ons of general up flow condensing units are limited such as apartments condos lofts multi families and high rise buildings and others named or unnamed Indoor unit s delivers the thermal and acoustical...

Страница 9: ...6 7 25 3 5 3 6 7 x 30 1 8 18 Cooling Speed SH H M L RPM 1300 1100 900 700 1350 1150 950 750 1400 1150 1000 850 1350 1150 1000 850 19 Heating Speed SH H M L RPM 1300 1140 980 820 1350 1190 1020 850 145...

Страница 10: ...s can be installed on a wall or balcony close to the indoor unit the following are some benefits for contractors and customers Each system is thoroughly tested before leaving the factory Each unit is...

Страница 11: ...27 6 37 9 37 6 Model 09K 12K 18K 24K Unit W 30 30 35 0 35 0 D1 12 6 21 3 11 3 12 6 21 3 11 3 15 6 22 0 22 0 14 3 14 3 15 6 D 10 1 10 1 13 4 13 4 P20 OF 44 USER NOTES AND SERVICE LOG 6 6 12 100 6 20 12...

Страница 12: ...Tape Level Flash Light Screw Driver Phillps and Flat Hammer Knife Scissors Goggled Glass Mask Gloves Ladder 2 Refrigeration Related Work RECOMMENDED TOOLS FOR INSTALLATION 3 Electrical Related Instal...

Страница 13: ...ors are to be used make sure to keep the two holes close to each other at least 2 inches apart Mounting plate should be attached to the structural part of the wall Minimum clearance as shown below is...

Страница 14: ...in condensing unit othewise condensate may ice up causing damage to the condensing unit Suggest to use YMGI provided brackets and condensate drainage fitting accessories Indoor unit front Bottom the r...

Страница 15: ...perpendicular to the pipe surface Don t cut too fast or too hard Turn and tighten the tube cutter slowly Remove residual left and de bur at the cutting edge The cutting edge should be clear and clean...

Страница 16: ...ation securely on the external wall with proper clamps at 6 feet apart Fill the gap between the wall hole and wall sleeve with putty to keep from rain or dust entering inside PIPING GUIDE Set the pack...

Страница 17: ...frigerant Charge Level Reference Temperature Pressure Table Split Condensing Unit R410A AC Product Series YMGI Group Mini Split Version 01 11 2010 Reference Temperature Pressure Table Split Condensing...

Страница 18: ...ng indoor fan motor works Heating all stop running 3s off blink four times 1 Forcibly lift up the panel at a specific angle from the two ends of the front panel following the arrow direction Then pull...

Страница 19: ...e is not staable cooling dehumidifying compressor will stop indoor fan motor works Heating all will stop 1 Check the Input voltage if the Voltage is lower than 150VAC restart the machine when the powe...

Страница 20: ...protection Heating LED Off 3S Blinks 6 times HE Compressor de managet protection rotor locked doesn t rotate Heating LED Off 3S Blinks 14 times L0 Airflow switch error TBD L1 Humidity sensor error TB...

Страница 21: ...uring gas sensor error Running LED Off 3S Blinks 21 times HP Solar AC solar power input voltage is higher than 180V TBD dA AHU or RT discharge air relative humidity sensor error TBD dE AHU or RT fresh...

Страница 22: ...r Cooling LED Off 3S Blinks 7 times FC Slide door error or air louver mechanism error TBD FE Over load sensor error TBD H8 Water level high overflow protection Heating LED Off 3S Blinks 8 times H9 Ele...

Страница 23: ...the unit and or know more details than anybody else They will check the unit and find out the problems with the professional knowledge about HVAC and electric product installation by using special to...

Отзывы: