21
“No” means, carry out crisscross cylinder test.
When the cylindrical power value C
≠
0, carry out crisscross cylinder test in the organized
sequence.
Set this item “Off”, carry out crisscross cylinder test in the organized sequence.
S.E.Fix(XC): on, off; factory default: on
Select if adjust spherical power value, so as to keep refraction spherical equivalency during
crisscross cylindrical test.
S.E.Fix(CYL): on, off; factory default: on
Select if adjust spherical power value, so as to keep refraction spherical equivalency during
crisscross cylindrical test.
Retinoscopy: +1.50D and +2.00D; factory default: +2.00D
Set spherical lens for retinoscopy.
N.V.illumination: on, Except Grid, off; factory default: on
If the short-distance indicator is automatically lit on when setting short-distance vision test.
Set it “On”: the short-distance indicator is automatically on during ADD testing mode and
short-distance vision test
Except grid: the short-distance indicator is automatically on during ADD testing mode and
short-distance vision test
But only when the cross-matrix sighting mark is used for near vision test, the short-distance
indicator is off.
Set it “Off”: the short-distance indicator is not automatically on.
F
→
N Link: SPH, SPH+ADD; factory default: SPH+ADD
Set the spherical value shifting from long-distance mode to short-distance mode.
SPH: the spherical value in long-distance mode is used in short-distance mode.
SPH+ADD: the additional power is added to the spherical value in the long-distance mode.
ADD Estimation: on, off; factory default: on
Set if pre-add additional power according to the age of the patient during short-distance vision test.
Working Distance : 35cm and 40cm; factory default: 40cm
Set working distance.
Содержание YPA-2100
Страница 1: ...YPA 2100 DIGITAL REFRACTOR User Manual Version 1 0 Date 20180521...
Страница 5: ...13 Electrical Schematic Diagram 82 14 Electromagnetic Compatibility 83...
Страница 24: ...19 Press to enlarge PD press to reduce PD 3 Press to exit PD input interface...
Страница 31: ...26 key...
Страница 42: ...37 4 Click key shift to 0 5XC 5 Click the key again shift to automatic mode Slit Prism...
Страница 55: ...50 34 Press to finish the test...
Страница 72: ...67 3 Program 1 A B C D are recommended vision test steps users can also add or delete as needed...
Страница 74: ...69 Add Key Click it to add one step automatically 4 Click key to enter program customizing interface...
Страница 78: ...73 3 Click key to popup input box...
Страница 79: ...74 4 Use CCQ 800 lensmeter to test lens data and convey the date to YPA 2100 5 Click key 6 Choose No00001...
Страница 80: ...75 7 Click key to complete data import...