With vector control, the carrier frequency is fixed to the Carrier Frequency Upper Limit in C6-03 if user-
set or by the carrier frequency set in C6-02.
•
To fix the carrier frequency, set C6-03 and C6-04 to the same value, or set C6-05 to 0.
•
If the settings are as shown below, OPE11 (Constant setting error) will occur.
If Carrier Frequency Proportional Gain (C6-05) > 6 and C6-03 < C6-04.
•
The Inverter overload current level can be reduced by the carrier frequency setting, and an OL2 (Inverter
overload) may be detected even if the overload current is smaller than 150%. The reduction levels of the
Inverter overload current are shown in the following figures.