1
Counter value
³
comparison value
®
output is set and
hysteresis
activated
2
Leave
hysteresis
range
®
output is reset
3
Counter value
³
comparison value
®
output is set and
hysteresis
activated
4
Leave
hysteresis
range, output remains set for
counter value
³
comparison value
5
counter value
<
comparison value
and
hysteresis
active
®
output is reset
6
counter value
³
comparison value
®
output is not set for
hysteresis
active
7
Leave
hysteresis
range, output remains set for
counter value
³
comparison value
With reaching the comparison condition the
hysteresis
gets active. At active
hysteresis
the comparison result remains unchanged until the
counter value
leaves the set
hyste-
resis
range. After leaving the
hysteresis
range a new
hysteresis
is only activated with
again reaching the comparison conditions.
1
Counter value
=
comparison value
®
output is set and
hysteresis
activated
2
Leave
hysteresis
range
®
output is reset and
counter value
<
comparison value
Effect at counter value
³
comparison value
Effect at pulse at compar-
ison value with pulse
duration Zero
VIPA System 300S
+
Deployment I/O periphery
Counter > Counter - Additional functions
HB140 | CPU-SC | 313-5BF23 | en | 19-01
126